The Simple Logger® II Model L564 is a 4-channel AC voltage and current recording device powered by alkaline batteries. Voltage inputs are directly measured up to 600VAC. Harmonic measurements are calculated from these 64 samples taken on each cycle measured and are only available from the Simple Logger® II Control Panel in the DataView® software.
The Simple Logger® II, Model L564, stores TRMS measurements at user programmable rates from eight times per second to one per day. TRMS calculations are performed on a single line cycle. The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.
Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. Bluetooth communication provides for the transfer of data from the instrument's internal memory to the computer for analysis.
Electrical | ||
Channels | Four (two voltage & two current) | |
Connection | Current Channel | Voltage Channel |
Input Connection | Two | Three recessed banana jacks |
Input Range | 0 to 1V ac *(for use with current probes with a voltage output) | 0 to 600V ac |
Resolution | 0.1mV | 0.1V |
Accuracy (50/60Hz) | 0 to 10mV unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV) | 0 to 5V unspecified 5 to 50V: ±(0.5% of Reading + 1V) 50 to 600V: ±(0.5% of Reading + 0.5V) |
Input Impedance | 100kΩ | 16MΩ |
Maximum Input Voltage | 5Vrms or ± 7.07V peak | 1.2 x 600V |
Sample Rate | 64 samples/cycle | |
Storage Rate | Programmable from 125ms to 1 per day | |
Storage Modes | Stop when full, FIFO, Extended Recording Mode (XRM™) and Store on Alarm | |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® | |
Memory | 1,000,000 measurements (2MB). The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. | |
Communication | Bluetooth (Class 2) | |
Power Source | 4 x 1.5V C-cell Alkaline batteries (included) | |
Battery Life | Up to 180 days (dependent on sample rate and recording length) | |
Mechanical | ||
Dimensions | 5.904 x 5.904 x 3.568" (150 x 150 x 91mm) w/o Sensor | |
Weight (with battery) | 2.1 lbs (0.95kg) | |
Case | UL94-VO | |
Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) | |
Shock | IEC 68-2-27 (30G) | |
Drop | IEC 68-2-32 (1m) | |
Environmental | ||
Operating Temperature | 14° to 122°F (-10° to 50°C) | |
Storage Temperature | -4° to 140°F (-20° to 60°C) | |
Relative Humidity | Up to 85% @ 95°F (35°C), Non-condensing |
Click on a category to view a selection of compatible accessories with the AEMC L564 4-Channel Voltage & Current Datalogger.
Electrical | ||
Channels | Four (two voltage & two current) | |
Connection | Current Channel | Voltage Channel |
Input Connection | Two | Three recessed banana jacks |
Input Range | 0 to 1V ac *(for use with current probes with a voltage output) | 0 to 600V ac |
Resolution | 0.1mV | 0.1V |
Accuracy (50/60Hz) | 0 to 10mV unspecified 10 to 50mV: ±(0.5% of Reading + 1mV) 50 to 1000mV: ±(0.5% of Reading + 0.5mV) | 0 to 5V unspecified 5 to 50V: ±(0.5% of Reading + 1V) 50 to 600V: ±(0.5% of Reading + 0.5V) |
Input Impedance | 100kΩ | 16MΩ |
Maximum Input Voltage | 5Vrms or ± 7.07V peak | 1.2 x 600V |
Sample Rate | 64 samples/cycle | |
Storage Rate | Programmable from 125ms to 1 per day | |
Storage Modes | Stop when full, FIFO, Extended Recording Mode (XRM™) and Store on Alarm | |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® | |
Memory | 1,000,000 measurements (2MB). The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. | |
Communication | Bluetooth (Class 2) | |
Power Source | 4 x 1.5V C-cell Alkaline batteries (included) | |
Battery Life | Up to 180 days (dependent on sample rate and recording length) | |
Mechanical | ||
Dimensions | 5.904 x 5.904 x 3.568" (150 x 150 x 91mm) w/o Sensor | |
Weight (with battery) | 2.1 lbs (0.95kg) | |
Case | UL94-VO | |
Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) | |
Shock | IEC 68-2-27 (30G) | |
Drop | IEC 68-2-32 (1m) | |
Environmental | ||
Operating Temperature | 14° to 122°F (-10° to 50°C) | |
Storage Temperature | -4° to 140°F (-20° to 60°C) | |
Relative Humidity | Up to 85% @ 95°F (35°C), Non-condensing |
Click on a category to view a selection of compatible accessories with the AEMC L564 4-Channel Voltage & Current Datalogger.