Ideal for electricians, engineers, and contractors working on residential and commercial energy audits or building and system monitoring and upgrades, this data logger measures, records, and analyzes vital energy data. In addition, this simple-to-use data-logger kit includes three MiniFlex sensors and a classic tool bag.
Ideal for electricians, engineers, and contractors working on residential and commercial energy audits or building and system monitoring and upgrades, this data logger measures, records, and analyzes vital energy data. In addition, this simple-to-use data-logger kit includes three MiniFlex sensors and a classic tool bag.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The replacement product is only available on our affiliate ITM.com website. Don't worry your cart and information will be brought over.
Our PEL100 loggers can track even the slightest consumption in a factory, workshop, building, agency, etc. They simultaneously allow real-time consumption monitoring alongside historical and comparative analysis of consumption.
Predictive maintenance:When installed for a long period in a cabinet, PEL100 loggers constantly monitor the active, apparent and reactive power values on the electrical network involved. This means it will instantly detect whenever the subscribed power threshold is exceeded.
With the software for automatically generating and printing reports, balance sheets, graphs or DataView summaries, users can act quickly on the cause of this overconsumption which will lead to higher bills. Indeed, every time your subscribed power threshold is exceeded, your bill will increase.
By setting up several PEL100 loggers on a general electrical distribution system, local authorities for example can simplify their consumption management by controlling the allocation of the different types of consumption:
Measuring the savings:
The recordings made with PEL100 electrical measuring instruments are time/datestamped. This makes it very simple to measure the gains achieved by comparing the recordings before and after modifying the installation.
The reference is provided by the recordings from the PEL100 loggers before the modifications were made. You can then carry out the necessary work for maintenance or improvement of the electrical network or equipment. A correctly-positioned PEL100 will quickly enable you to target the places where work is needed without delay. Finally, a monitoring phase will help you to determine whether the solutions implemented are sufficient and, above all, to accurately measure any savings achieved. The monitoring by the PEL100 provides the recordings which will be compared with the reference.
General | |
Sampling Frequency | 128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz) |
Data Storage Rate | 1 per second |
Demand Period Storage Rate | User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes) |
Recorded Parameters (Single- and Poly-Phase) | V, I, W, VA, var, PF, Tan, Wh, Vah, varh, THD (V and I) Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF |
Event Log | Tracks and records status changes and error messages along with recorded data |
Front Panel Indicator LEDs | Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status |
Storage Capacity | 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported |
Inputs | Voltage: 3 voltage input channels via 4mm safety banana jacks Current: 3 current input channels via custom 4 pin jacks that accept AEMC® probes and sensors |
Mechanical | |
Communication Ports | USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class |
Dimension/Weight | 10.08 x 4.92 x 1.46" (256 x 125 x 37mm) / <1kg |
Case / Index of Protection | Double insulated, rubber over-molded, polycarbonate UL94 V1 rated / IP54 non operating |
Mounting / Security | Embedded magnets on back side, keyhole slot on back side / Kensington anti-theft system |
Safety Rating / CE Rating | Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III / 600V CAT IV, Pollution Degree 2 / Yes |
Click on a category to view a selection of compatible accessories with the AEMC PEL 102 Power/Energy Data Logger Kit with sensors.
General | |
Sampling Frequency | 128 samples per cycle; 50/60Hz (16 samples/cycle 400Hz) |
Data Storage Rate | 1 per second |
Demand Period Storage Rate | User selectable (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30 and 60 minutes) |
Recorded Parameters (Single- and Poly-Phase) | V, I, W, VA, var, PF, Tan, Wh, Vah, varh, THD (V and I) Individual harmonics (from 1 through 50 per phase); Crest Factor (CF), Cos f / DPF |
Event Log | Tracks and records status changes and error messages along with recorded data |
Front Panel Indicator LEDs | Bluetooth active, recording in progress, phase connection reversal, overload, battery charging and SD Card status |
Storage Capacity | 2GB SD card (included) is used for storage. SD cards (up to 2GB); SDHC cards (4 to 32GB) formatted FAT32 are supported |
Inputs | Voltage: 3 voltage input channels via 4mm safety banana jacks Current: 3 current input channels via custom 4 pin jacks that accept AEMC® probes and sensors |
Mechanical | |
Communication Ports | USB 2.0, Ethernet (RJ45), Wireless Bluetooth Class |
Dimension/Weight | 10.08 x 4.92 x 1.46" (256 x 125 x 37mm) / <1kg |
Case / Index of Protection | Double insulated, rubber over-molded, polycarbonate UL94 V1 rated / IP54 non operating |
Mounting / Security | Embedded magnets on back side, keyhole slot on back side / Kensington anti-theft system |
Safety Rating / CE Rating | Complies with IEC 61010-1:Ed3, and IEC 61010-2-030:Ed1 for 1000V CAT III / 600V CAT IV, Pollution Degree 2 / Yes |
Click on a category to view a selection of compatible accessories with the AEMC PEL 102 Power/Energy Data Logger Kit with sensors.