Eight-channel data logger has 8 configurable analog inputs that can measure thermocouples, Pt100, Pt1000, DC voltage and DC current signals. Equipped with 2 relay outputs and 8 digital ports that are individually configurable as inputs or outputs. Note: This model does not include LCD display.
Eight-channel data logger has 8 configurable analog inputs that can measure thermocouples, Pt100, Pt1000, DC voltage and DC current signals. Equipped with 2 relay outputs and 8 digital ports that are individually configurable as inputs or outputs. Note: This model does not include LCD display.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Current Dataloggers category for similar products.
Or let's do a search and help you find what you need:
The 8-Channel Data Logger Model DL-1080 (no display) is a versatile, powerful and cost effective data logger handling analog, digital and other types of variables with high resolution and speed. It offers high performance and is easy to configure and operate.
The Model DL-1080 has 8 configurable analog inputs that can measure thermocouples, Pt100, Pt1000, DC voltage and DC current signals. It is equipped with 2 relay outputs and 8 digital ports that are individually configurable as inputs or outputs.
Up to 128 math channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, e-mails and SNMP trap sending.
The RS485 interface can operate as a Modbus RTU master or slave. As a master, it can read and log up to 64 external channels. A 10/100Mbps Ethernet interface allows access through a browser (HTTP), FTP (client and server), e-mails sending (SMTP), SNMP and Modbus TCP.
The Model DL-1080 has a mini USB interface for connecting to a computer for configuration, monitoring and data download and another USB port for plugging in a flash drive for data retrieval. The 512k internal basic memory is used to store data and can be greatly expanded with an SD card up to 16GB.
Features
Applications
Internal Memory | 2MB |
Power | 100 to 240V AC, 50/60Hz. 20VA (Max) |
Analog Channels Input Impedance | Thermocouples / Pt100 / Pt1000 / mV: > 2MΩ mA: 15Ω + 1.5V V: 1.1MΩ |
Accuracy | Thermocouples J, K, T, E and N: 0.2% of the span ± 1°C
Thermocouples R, S and B: 0.2% of the span ± 3°C Pt100, Pt1000, 0 to 20mA, 4 to 20mA, 0 to 20mV, 0 to 50mV, 0 to 60mV, -20 to 20mV, 0 to 5V and 0 to 10V: 0.15% of the span |
Excitation Current | Pt100s: 360µA; Pt1000s: 320µA |
Maximum Pt100/Pt1000 Compensated Cable Resistance | 40Ω |
Digital Inputs | Logic level "0": from 0 to 0.8V DC Logic level "1": from 3 to 30V DC |
Maximum Input Voltage | 30V DC |
Input Current at 30V DC (typical) | 3mA |
Digital Outputs | Maximum output voltage: 30V DC Maximum output current: 200mA Maximum relay current: 3A at 250V AC; 3A at 30V DC |
Storage Rate | From 1ms to 24 hours |
Maximum Channel Logged | 100 |
Supported Modbus Commands | Read Coil Status (01h) Read Holding Registers (03h) Write Single Coil (05h) Write Single Register (06h) Write Multiple Registers (0Fh) |
Click on a category to view a selection of compatible accessories with the AEMC DL-1080 8-Channel Data Logger.
Internal Memory | 2MB |
Power | 100 to 240V AC, 50/60Hz. 20VA (Max) |
Analog Channels Input Impedance | Thermocouples / Pt100 / Pt1000 / mV: > 2MΩ mA: 15Ω + 1.5V V: 1.1MΩ |
Accuracy | Thermocouples J, K, T, E and N: 0.2% of the span ± 1°C
Thermocouples R, S and B: 0.2% of the span ± 3°C Pt100, Pt1000, 0 to 20mA, 4 to 20mA, 0 to 20mV, 0 to 50mV, 0 to 60mV, -20 to 20mV, 0 to 5V and 0 to 10V: 0.15% of the span |
Excitation Current | Pt100s: 360µA; Pt1000s: 320µA |
Maximum Pt100/Pt1000 Compensated Cable Resistance | 40Ω |
Digital Inputs | Logic level "0": from 0 to 0.8V DC Logic level "1": from 3 to 30V DC |
Maximum Input Voltage | 30V DC |
Input Current at 30V DC (typical) | 3mA |
Digital Outputs | Maximum output voltage: 30V DC Maximum output current: 200mA Maximum relay current: 3A at 250V AC; 3A at 30V DC |
Storage Rate | From 1ms to 24 hours |
Maximum Channel Logged | 100 |
Supported Modbus Commands | Read Coil Status (01h) Read Holding Registers (03h) Write Single Coil (05h) Write Single Register (06h) Write Multiple Registers (0Fh) |
Click on a category to view a selection of compatible accessories with the AEMC DL-1080 8-Channel Data Logger.