The PEL 112 is a cost-effective, easy-to-use power and energy data logger that supports single-phase, split-phase, and three-phase (Y, Δ) systems. Ideal for electricians, engineers, and contractors, it is perfect for building and system monitoring, upgrades, and energy audits. It accurately measures, records, and analyzes vital energy data, generating standard and customizable reports with minimal setup.
The PEL 112 is a cost-effective, easy-to-use power and energy data logger that supports single-phase, split-phase, and three-phase (Y, Δ) systems. Ideal for electricians, engineers, and contractors, it is perfect for building and system monitoring, upgrades, and energy audits. It accurately measures, records, and analyzes vital energy data, generating standard and customizable reports with minimal setup.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
The replacement product is only available on our affiliate ITM.com website. Don't worry your cart and information will be brought over.
Designed for convenience, the PEL 110 series can be installed inside a load center panel—sensors included—while allowing the panel door to close in most cases. These loggers provide all essential power/energy monitoring functions for 17 different electrical network setups worldwide.
Features
The PEL 112 measures and records all power and energy data. It is designed for use anywhere electricity is present, including:
Applications
Compact and User-Friendly Design
Comprehensive Power Measurements
Advanced Features
DataView® Software
The DataView® software simplifies setup, monitoring, and analysis:
Network Communication
The PEL 112 offers multiple connectivity options:
General Specifications | |
Number of Voltage Inputs | 3 (V1, V2, V3) |
Number of Current Inputs | 3 (L1, L2, L3) |
Distribution Systems | Single-/Split-/3-phase, DC, etc. (17 choices) |
Measurements | |
Voltage Range - Phase-Neutral (V) | (10 to 1000) V AC/DC 2 |
Voltage Range - Phase-Phase (U) | (10 to 1000) V AC 2 |
Typical Accuracy - Voltage | ± 0.2% R ± 0.2 V |
Current Range AC | 200 mA to 12 kA AC |
Current Range DC | 50 mA to 1300 ADC 3 |
Typical Accuracy - Current -(Meter Only) 4 | ± 0.4 % R ± 0.04 % Inom |
Network Frequencies | DC/50/60/400 Hz (VFD/PWM not available) |
Calculated Measurements | |
Voltage Ratios | up to 650 kV |
Current Ratios | Not available with AmpFlex®/MiniFlex® sensors |
Power (P, P+ , Punb, Qf, N, D, S) | up to 10 GW/Gvar/GVA 5 |
Energy | up to 4 EWh/EVAh/Evarh 5 |
Phase | cos φ, tan Φ, PF |
Phase Order / Phasor Diagram | Yes / Yes (with DataView® or App for Android) |
Harmonics | THD for V, A and harmonics to 50th order for V, A |
Recording | |
Aggregations (Fixed) | 200 ms/1 s trends |
Aggregations (Selectable) | (1 to 60) min (12 choices) |
Min/Max Values | Yes |
Alarms | up to 32 separate alarms |
Emailed Reports | Yes, Alarms and Periodical Min/Max data through DataViewSync® |
Storage Media | SD Card (32 GB Max) |
Recording Length | Several weeks to years (Configuration dependent) |
Other Features | |
Communication | USB, Ethernet Wi-Fi LAN, Ethernet/Wi-Fi Direct, DataViewSync® |
Software | DataView® included, free App for Android™ |
NEC Article 220.87 - Load Study Compliant | Yes, DataView® configuration button and report templates |
Mounting | Embedded magnets in case |
Powered from phase voltage | Phase Power Adapter (Catalog #2137.90) |
External Power Supply | 120 / 240 V Line Power Cord |
Safety and Mechanical | |
Electrical Safety | 600 V CAT IV / 1000 V CAT III |
Ingress Protection | IP 54 / IP 20 |
Weight | < 2.2 lbs (1 kg) |
Click on a category to view a selection of compatible accessories with the AEMC PEL 112 Power and Energy Logger with BK sensors.
General Specifications | |
Number of Voltage Inputs | 3 (V1, V2, V3) |
Number of Current Inputs | 3 (L1, L2, L3) |
Distribution Systems | Single-/Split-/3-phase, DC, etc. (17 choices) |
Measurements | |
Voltage Range - Phase-Neutral (V) | (10 to 1000) V AC/DC 2 |
Voltage Range - Phase-Phase (U) | (10 to 1000) V AC 2 |
Typical Accuracy - Voltage | ± 0.2% R ± 0.2 V |
Current Range AC | 200 mA to 12 kA AC |
Current Range DC | 50 mA to 1300 ADC 3 |
Typical Accuracy - Current -(Meter Only) 4 | ± 0.4 % R ± 0.04 % Inom |
Network Frequencies | DC/50/60/400 Hz (VFD/PWM not available) |
Calculated Measurements | |
Voltage Ratios | up to 650 kV |
Current Ratios | Not available with AmpFlex®/MiniFlex® sensors |
Power (P, P+ , Punb, Qf, N, D, S) | up to 10 GW/Gvar/GVA 5 |
Energy | up to 4 EWh/EVAh/Evarh 5 |
Phase | cos φ, tan Φ, PF |
Phase Order / Phasor Diagram | Yes / Yes (with DataView® or App for Android) |
Harmonics | THD for V, A and harmonics to 50th order for V, A |
Recording | |
Aggregations (Fixed) | 200 ms/1 s trends |
Aggregations (Selectable) | (1 to 60) min (12 choices) |
Min/Max Values | Yes |
Alarms | up to 32 separate alarms |
Emailed Reports | Yes, Alarms and Periodical Min/Max data through DataViewSync® |
Storage Media | SD Card (32 GB Max) |
Recording Length | Several weeks to years (Configuration dependent) |
Other Features | |
Communication | USB, Ethernet Wi-Fi LAN, Ethernet/Wi-Fi Direct, DataViewSync® |
Software | DataView® included, free App for Android™ |
NEC Article 220.87 - Load Study Compliant | Yes, DataView® configuration button and report templates |
Mounting | Embedded magnets in case |
Powered from phase voltage | Phase Power Adapter (Catalog #2137.90) |
External Power Supply | 120 / 240 V Line Power Cord |
Safety and Mechanical | |
Electrical Safety | 600 V CAT IV / 1000 V CAT III |
Ingress Protection | IP 54 / IP 20 |
Weight | < 2.2 lbs (1 kg) |
Click on a category to view a selection of compatible accessories with the AEMC PEL 112 Power and Energy Logger with BK sensors.