Use this data logger to record measurements of voltage, resistance, temperature and more. The logger is equipped with 30 isolated channels.
Use this data logger to record measurements of voltage, resistance, temperature and more. The logger is equipped with 30 isolated channels.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Equipped with 30 analog and 8 pulse and digital channels, this Hioki LR8401-20 Memory HiLogger makes it easy to measure temperature, voltage, resistance and more. Each channel is isolated and can handle up to 300 VAC, DC from the terminals to the ground. The data logger can be connected to your PC to record data in real time with the USB and LAN connections.
Features
Number of Channels | 30 analog with isolated scanning method input (4 push-button terminals), 8 pulse/digital selectable |
Voltage | ±10 mV to ±100 V, 1 to 5 V full scale with 500nV maximum resolution |
Thermocouple Temperature | -328 to 3,632°F (-200 to 2,000°C) K, J, E, T, N, R, S, B, W with 0.01°C maximum resolution |
Temperature Sensor | -328 to 1,472°F (-200 to 800°C) Pt 100 and JPt 100 sensors with 0.01°C maximum resolution |
Resistance | 0 to 200 Ω full scale with a 0.5m Ω maximum resolution |
Humidity | 5 to 95% relative humidity (use with optical sensor) with 0.1% relative humidity resolution |
Maximum Rated Voltage | Between Isolated Input Channels: 300 VDC, From Isolated Terminals to Ground: 300 VAC, VDC |
Maximum Allowable Input | Analog: ±100 VDC, Pulse/Digital: 0 to 50 V |
Pulse Totalization | 0 to 1,000M pulse |
Rotation Count | 0 to 5,000/n (r/s) full scale |
Power Supply | 9418-15 AC adapter, Z1000 battery pack, 10 to 28 VDC external power supply |
Recording Interval | 10 to 50 ms, 100 ms to 1 hour, 19 selections |
Storage | 8M-words (internal memory), CF card or USB flash drive |
Display | 5.7" (14.48 cm) TFT LCD with 640 x 480 resolution |
Interface | USB 2.0 mini-B, 100Base-TX |
Product Length | 2.62" (66.5 mm) |
Product Width | 10.71" (272 mm) |
Product Height | 7.18" (182.4 mm) |
Product Weight | 63.5oz (1.8 kg) |
Manufacturer Warranty | 3-year limited |
Number of Channels | 30 analog with isolated scanning method input (4 push-button terminals), 8 pulse/digital selectable |
Voltage | ±10 mV to ±100 V, 1 to 5 V full scale with 500nV maximum resolution |
Thermocouple Temperature | -328 to 3,632°F (-200 to 2,000°C) K, J, E, T, N, R, S, B, W with 0.01°C maximum resolution |
Temperature Sensor | -328 to 1,472°F (-200 to 800°C) Pt 100 and JPt 100 sensors with 0.01°C maximum resolution |
Resistance | 0 to 200 Ω full scale with a 0.5m Ω maximum resolution |
Humidity | 5 to 95% relative humidity (use with optical sensor) with 0.1% relative humidity resolution |
Maximum Rated Voltage | Between Isolated Input Channels: 300 VDC, From Isolated Terminals to Ground: 300 VAC, VDC |
Maximum Allowable Input | Analog: ±100 VDC, Pulse/Digital: 0 to 50 V |
Pulse Totalization | 0 to 1,000M pulse |
Rotation Count | 0 to 5,000/n (r/s) full scale |
Power Supply | 9418-15 AC adapter, Z1000 battery pack, 10 to 28 VDC external power supply |
Recording Interval | 10 to 50 ms, 100 ms to 1 hour, 19 selections |
Storage | 8M-words (internal memory), CF card or USB flash drive |
Display | 5.7" (14.48 cm) TFT LCD with 640 x 480 resolution |
Interface | USB 2.0 mini-B, 100Base-TX |
Product Length | 2.62" (66.5 mm) |
Product Width | 10.71" (272 mm) |
Product Height | 7.18" (182.4 mm) |
Product Weight | 63.5oz (1.8 kg) |
Manufacturer Warranty | 3-year limited |