The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 4 x 3-phase meters or 12 channels.
The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 4 x 3-phase meters or 12 channels.
The multi-circuit meter controls current, voltage, power and harmonic distortion (THD). Accommodates 4 x 3-phase meters or 12 channels.
Features
Applications
| Measurement Voltage | 90 to 300 VAC line-to-neutral, 50/60 Hz |
| Control Power | 100 to 277 VAC line-to-neutral, 50/60 Hz, 15VA |
| Power/Energy | IEC 62053-21 Class 0.5, ANSI C12.20 Class 0.5 |
| Voltage | ±0.5% of reading 90 to 277 V line-to-neutral |
| Current | ±0.5% of reading from 2 to 100% full scale |
| Sampling Frequency | 2,560 Hz |
| Update Rate | 2 seconds (both panels) |
| Overload Capability | 22 kAIC |
| Physical Interface | 2-wire RS-485 |
| Protocols Supported | Modbus RTU or BACnet MSTP |
| Address | 1 to 247 for Modbus RTU; 0 to 127 for BACnet MS/TP |
| Baud Rate | 9600, 19200, 38400 |
| Parity | Modbus RTU: NONE, ODD, EVEN; BACnet MS/TP: NONE (fixed) |
| Physical Interface | RJ45 connector with 10/100 Mbit Ethernet |
| Protocols Supported | Modbus TCP, BACnet IP, SNMP V2c |
| Removable Connectors | 4.4 to 5.3 in-lb (0.5 to 0.6 N-m) |
| Operating Temperature | 32 to 140°F (0 to 60°C) <95% RH non-condensing |
| Storage Temperature | -40 to 158°F (-40 to 70°C) |
| Altitude of Operation | 9,842.5' (3,000 m) |
| Mounting Location | Indoor use, dry location |
| Warranty | 5 years limited |
| Agency Approvals | IEC/EN61010-1 |
| Installation Category | Cat III, pollution degree 2 |
| Measurement Voltage | 90 to 300 VAC line-to-neutral, 50/60 Hz |
| Control Power | 100 to 277 VAC line-to-neutral, 50/60 Hz, 15VA |
| Power/Energy | IEC 62053-21 Class 0.5, ANSI C12.20 Class 0.5 |
| Voltage | ±0.5% of reading 90 to 277 V line-to-neutral |
| Current | ±0.5% of reading from 2 to 100% full scale |
| Sampling Frequency | 2,560 Hz |
| Update Rate | 2 seconds (both panels) |
| Overload Capability | 22 kAIC |
| Physical Interface | 2-wire RS-485 |
| Protocols Supported | Modbus RTU or BACnet MSTP |
| Address | 1 to 247 for Modbus RTU; 0 to 127 for BACnet MS/TP |
| Baud Rate | 9600, 19200, 38400 |
| Parity | Modbus RTU: NONE, ODD, EVEN; BACnet MS/TP: NONE (fixed) |
| Physical Interface | RJ45 connector with 10/100 Mbit Ethernet |
| Protocols Supported | Modbus TCP, BACnet IP, SNMP V2c |
| Removable Connectors | 4.4 to 5.3 in-lb (0.5 to 0.6 N-m) |
| Operating Temperature | 32 to 140°F (0 to 60°C) <95% RH non-condensing |
| Storage Temperature | -40 to 158°F (-40 to 70°C) |
| Altitude of Operation | 9,842.5' (3,000 m) |
| Mounting Location | Indoor use, dry location |
| Warranty | 5 years limited |
| Agency Approvals | IEC/EN61010-1 |
| Installation Category | Cat III, pollution degree 2 |