Enercept Series transducers combine the processing electronics into industrial grade split-core CTs so they are faster and easier to install that traditional metering systems. The H8041/8043 series includes 4-20mA output.
Enercept Series transducers combine the processing electronics into industrial grade split-core CTs so they are faster and easier to install that traditional metering systems. The H8041/8043 series includes 4-20mA output.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
Not what you're looking for? Let’s do a search and help you find what you need.
The EnerceptH804x and H805x Series kW (real power)/kWh (consumption)
transducers combine processing electronics and industrial grade CTs in an easy-toinstall split-core package. These devices continuously measure voltage and current
values for the monitored conductors and update calculations to provide highly
accurate true RMS power readings. Models designed for balanced loads include one
CT only, while models for unbalanced loads have three CTs.
The unique design of the H804x/H805x Series transducers reduces the number
of installed components, making them ideal for monitoring electrical power in
commercial and industrial facilities The H804x provides industry-standard 4-20mA
output, and the H805x provides a pulse output.
Installation is simple. The H804x/H805x eliminates the need to mount and wire a
transducer and enclosure. CTs and voltage leads are color-matched, and the meters
are designed to detect and automatically compensate for phase reversal. No more
worries about CT load orientation.
† Contact factory to interface with voltages above 480 VAC or current above 2400 Amps.
†† Do not apply 600V Class current transformers to circuits having a phase-to-phase voltage greater than 600V, unless adequate additional insulation is applied between the primary conductor and the current transformers. Veris assumes no responsibility for damage of equipment or personal injury caused by products operated on circuits above their published ratings.
* Count must be multiplied by the number of phases when using single CT models to monitor balanced multiphase systems.
† Contact factory to interface with voltages above 480 VAC or current above 2400 Amps.
†† Do not apply 600V Class current transformers to circuits having a phase-to-phase voltage greater than 600V, unless adequate additional insulation is applied between the primary conductor and the current transformers. Veris assumes no responsibility for damage of equipment or personal injury caused by products operated on circuits above their published ratings.
* Count must be multiplied by the number of phases when using single CT models to monitor balanced multiphase systems.