Perfect solution for connecting new or existing Modbus and pulse devices (meters, sensors, etc.) without the need for costly wiring runs, core drilling or conduit. Simply connect the Modbus RTU devices to the serial port on the Modhopper and the transceivers will automatically detect the optimum routing to insure reliable and timely data communications.
Perfect solution for connecting new or existing Modbus and pulse devices (meters, sensors, etc.) without the need for costly wiring runs, core drilling or conduit. Simply connect the Modbus RTU devices to the serial port on the Modhopper and the transceivers will automatically detect the optimum routing to insure reliable and timely data communications.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Wireless MODBUS Networks category for similar products.
Or let's do a search and help you find what you need:
Applications
Processor | 60MHz ARM7 embedded CPU |
LEDs | 3 x RF, 2 x RS-485, 2 x Pulse, Alive, Alarm |
Communication | |
Protocols | Modbus RTU, 2-wire |
Addressing | Modbus address may be set from 1 to 247 via dipswitch |
Baud Rate | 9600/19200 baud, N, 8, 1 |
RF | Frequency hopping, spread spectrum (FHSS), ISM band |
Inputs | |
I/O | 2x Pulse, dry contact, standard or KYZ, closure threshold 100Ω to 2.5Ω user selectable |
Pulse Rate | User selectable to 10Hz, 50Hz, 100Hz, 250Hz Pulse rate option 10Hz, minimum pulse width 50ms Pulse rate option 50Hz, minimum pulse width 10ms Pulse rate option 100Hz, minimum pulse width 5ms Pulse rate option 250Hz, minimum pulse width 2m |
Storage | Pulse counts stored in non-volatile memory |
Modbus | Modbus RTU, 2-wire, hard-wire connect up to 32 devices (expandable) |
Processor | 60MHz ARM7 embedded CPU |
LEDs | 3 x RF, 2 x RS-485, 2 x Pulse, Alive, Alarm |
Communication | |
Protocols | Modbus RTU, 2-wire |
Addressing | Modbus address may be set from 1 to 247 via dipswitch |
Baud Rate | 9600/19200 baud, N, 8, 1 |
RF | Frequency hopping, spread spectrum (FHSS), ISM band |
Inputs | |
I/O | 2x Pulse, dry contact, standard or KYZ, closure threshold 100Ω to 2.5Ω user selectable |
Pulse Rate | User selectable to 10Hz, 50Hz, 100Hz, 250Hz Pulse rate option 10Hz, minimum pulse width 50ms Pulse rate option 50Hz, minimum pulse width 10ms Pulse rate option 100Hz, minimum pulse width 5ms Pulse rate option 250Hz, minimum pulse width 2m |
Storage | Pulse counts stored in non-volatile memory |
Modbus | Modbus RTU, 2-wire, hard-wire connect up to 32 devices (expandable) |