1.800.561.8187

information@ITM.com

Customer Reviews

Veris E31C42 Panelboard Monitoring System

Model: E31C42

Veris E31C42 Panelboard Monitoring System-


Downloads: manual

Veris E31C42 Panelboard Monitoring System

Model: E31C42

Basic Monitoring - Current for two 3-phase mains, two neutrals, and current for 42 50A branch circuits, Modbus, 90 - 277VAC (L-N), ribbon cables purchased separately (see CBL), can support 100A CTs sold separately.

Basic Monitoring - Current for two 3-phase mains, two neutrals, and current for 42 50A branch circuits, Modbus, 90 - 277VAC (L-N), ribbon cables purchased separately (see CBL), can support 100A CTs sold separately.

Sale Price $5008.00 CAD
Regular Price $10790.00 CAD
Availability 2 to 3 Weeks
Quantity

Monitor Current, Voltage, and Energy Consumption with One Device

Key Features

  • Revenue Grade measurements
  • IEC Class 1 metering accuracy
  • Up to 126 panelboards can be monitored on one RS-485 drop, simplifies wiring
  • Reports volts, amps, power, and energy for each circuit, one product covers the whole panelboard
  • 92 circuits with one product (84 branch circuits, 2 3-phase mains, 2 neutrals), saves space
  • 3/4", or 1", or 18 mm spaced solid-core current sensors, flexible installation
  • Split-core version has two mounting options (DIN Rail or Snaptrack), installation flexibility
  • 4 user-configurable alarm threshold registers, improved load management
  • Built-in ability to set the orientation and numbering of the circuits
  • 1/4 amp to 100 amp solid-core monitoring, widest dynamic range in the industry
  • 1, 2, 3 pole breaker support
  • Applications for new construction (solid-core version) and retrofits (split-core version)
  • Modbus RTU standard

E31A kits

Features advanced functionality monitor voltage, current, power and energy consumption of each circuit in a panelboard including the main breaker. The accumulated information can be transmitted through the communications interface. Data updates occur roughly every two seconds to provide timely preventative maintenance information. As any circuit approaches the user-configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.

E31B kits

Features intermediate functionality monitor voltage, current, power and energy consumption in the mains along with voltage and current in the branches in a panelboard. The accumulated information can be transmitted through the communications interface. Data updates occur roughly every two seconds to provide timely preventative maintenance information. As any circuit approaches the user-configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.

E31C kits

Features basic functionality monitor current in the mains and the branches in a panelboard. The accumulated information can be transmitted through the communications interface. Data updates occur roughly every two seconds to provide timely preventative maintenance information. As any circuit approaches the user-configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.

Applications

  • Retrofit branch circuit monitoring into existing panels
  • Load based cost allocation
  • Overload protection
  • Load management
  • Load balancing
  • Lighting circuits

Veris E31C42 Specifications

Inputs
Input Power 90 to 277 VAC, 50/60 Hz
Accuracy
Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Operation
Sampling Frequency 2560 Hz
Update Rate 1.8 Seconds
Overload Capability 22 kAIC
Network Communications
Type Modbus RTU
Connection DIP switch-selectable 2-wire or 4-wire, RS-485
Address DIP switch-selectable address 1 to 247 (pairs of 2)
Baud Rate DIP switch-selectable 9600, 19200, 38400
Parity DIP switch-selectable NONE, ODD, EVEN
Communication Format 8 data-bits, 1 start-bit, 1 stop-bit
Mechanical
Ribbon Cable Support 2 each 4' (0.9 m) flat ribbon cables ship standard; up to 20' (6 m) available
Environmental
Temperature Operating: 32 to 140°F (0 to 60°C)
Storage: -40 to 158°F (-40 to 70°C)

What's included with the Veris E31C42

  • Veris E31C42 Panelboard Monitoring System

Veris E31 Series Comparison

Monitoring at Mains E31A E31B E31C
Current per phase
Max. current per phase
Current demand per phase
Max. current demand per phase
Energy (kWh) per phase
Real Power (kW) per phase
Apparent Power (kVA)
Power factor total *
Power factor per phase
Voltage, L-L and average
Voltage, L-N and average
Voltage, L-N and per phase
Frequency (phase A)
Monitoring at Branch Circuit
Current
Max. current
Current demand
Max. current demand
Real power (kW)
Real power (kW) demand
Real power (kW) demand max.
Energy (kWh) per circuit
Power factor
Apparent Power (kVA)
Modbus Alarms
Voltage over/under
Current over/under

* Based on a 3-phase breaker rotation.

Ask a question about Veris E31C42 Panelboard Monitoring System

Customer Reviews for the Veris E31C42

Monitor Current, Voltage, and Energy Consumption with One Device

Key Features

  • Revenue Grade measurements
  • IEC Class 1 metering accuracy
  • Up to 126 panelboards can be monitored on one RS-485 drop, simplifies wiring
  • Reports volts, amps, power, and energy for each circuit, one product covers the whole panelboard
  • 92 circuits with one product (84 branch circuits, 2 3-phase mains, 2 neutrals), saves space
  • 3/4", or 1", or 18 mm spaced solid-core current sensors, flexible installation
  • Split-core version has two mounting options (DIN Rail or Snaptrack), installation flexibility
  • 4 user-configurable alarm threshold registers, improved load management
  • Built-in ability to set the orientation and numbering of the circuits
  • 1/4 amp to 100 amp solid-core monitoring, widest dynamic range in the industry
  • 1, 2, 3 pole breaker support
  • Applications for new construction (solid-core version) and retrofits (split-core version)
  • Modbus RTU standard

E31A kits

Features advanced functionality monitor voltage, current, power and energy consumption of each circuit in a panelboard including the main breaker. The accumulated information can be transmitted through the communications interface. Data updates occur roughly every two seconds to provide timely preventative maintenance information. As any circuit approaches the user-configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.

E31B kits

Features intermediate functionality monitor voltage, current, power and energy consumption in the mains along with voltage and current in the branches in a panelboard. The accumulated information can be transmitted through the communications interface. Data updates occur roughly every two seconds to provide timely preventative maintenance information. As any circuit approaches the user-configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.

E31C kits

Features basic functionality monitor current in the mains and the branches in a panelboard. The accumulated information can be transmitted through the communications interface. Data updates occur roughly every two seconds to provide timely preventative maintenance information. As any circuit approaches the user-configured thresholds, alarm indicators are triggered, preventing costly downtime from overloaded circuits or failed loads.

Applications

  • Retrofit branch circuit monitoring into existing panels
  • Load based cost allocation
  • Overload protection
  • Load management
  • Load balancing
  • Lighting circuits

Veris E31C42 Specifications

Inputs
Input Power 90 to 277 VAC, 50/60 Hz
Accuracy
Power/Energy IEC 62053-21 Class 1, ANSI C12.1-2008
Voltage ±0.5% of reading 90 to 277 V line-to-neutral
Operation
Sampling Frequency 2560 Hz
Update Rate 1.8 Seconds
Overload Capability 22 kAIC
Network Communications
Type Modbus RTU
Connection DIP switch-selectable 2-wire or 4-wire, RS-485
Address DIP switch-selectable address 1 to 247 (pairs of 2)
Baud Rate DIP switch-selectable 9600, 19200, 38400
Parity DIP switch-selectable NONE, ODD, EVEN
Communication Format 8 data-bits, 1 start-bit, 1 stop-bit
Mechanical
Ribbon Cable Support 2 each 4' (0.9 m) flat ribbon cables ship standard; up to 20' (6 m) available
Environmental
Temperature Operating: 32 to 140°F (0 to 60°C)
Storage: -40 to 158°F (-40 to 70°C)

What's included with the Veris E31C42

  • Veris E31C42 Panelboard Monitoring System

Veris E31 Series Comparison

Monitoring at Mains E31A E31B E31C
Current per phase
Max. current per phase
Current demand per phase
Max. current demand per phase
Energy (kWh) per phase
Real Power (kW) per phase
Apparent Power (kVA)
Power factor total *
Power factor per phase
Voltage, L-L and average
Voltage, L-N and average
Voltage, L-N and per phase
Frequency (phase A)
Monitoring at Branch Circuit
Current
Max. current
Current demand
Max. current demand
Real power (kW)
Real power (kW) demand
Real power (kW) demand max.
Energy (kWh) per circuit
Power factor
Apparent Power (kVA)
Modbus Alarms
Voltage over/under
Current over/under

* Based on a 3-phase breaker rotation.

Ask a question about Veris E31C42 Panelboard Monitoring System

Customer Reviews for the Veris E31C42

More Veris Products