Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC, 0.75 inches

Model: SCT-075R-100

Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC,  0.75 inches-


Downloads: datasheet

Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC, 0.75 inches

Model: SCT-075R-100

Current Transformer with a 0.333 voltage output, 0.75 inch opening, and a rating up to 100 amps.

Current Transformer with a 0.333 voltage output, 0.75 inch opening, and a rating up to 100 amps.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Magnelab SCT-075H-100 Revenue Grade Split-Core AC Current Sensor-

Magnelab SCT-075H-100 Revenue Grade Split-Core AC Current Sensor

Model: SCT-075H-100

0.75" Opening with Ratings Up to 50 Amps


Magnelab SCT-075R-100 Offers

Magnelab's SCT-075R Series Current Sensors meets ANSI C57.13 revenue grade accuracy class 0.6 with unprecedented linearity and superior phase angle up to 100 Amps passing through the center conductor. Split-core transformers are ideal for installation on electrical wiring by snapping around the conductor. The SCT Series have a self-locking mechanism.

Features

  • Rated input up to 100 Amps
  • Output of 0.333 Volt at rated current
  • Linearity accuracy ± 0.5%
  • Accuracy at 10% to 120% of rated current
  • Phase angle 0.25°
  • 8 ft. twisted-pair lead, 22 AWG
  • Maximum Voltage: 600 V (on bare conductor)
  • UL recognized, CE, and RoHS compliant
  • Other parameters are available at customer request

Magnelab SCT-075R-100 Specifications

Input 100 Amps
Output 0.333 Volt at rated current
Linearity Accuracy ± 0.5%
Accuracy 10% to 120% of rated current
Max. Voltage 600 Volts (on bare conductor)
Click here for complete specifications on the Magnelab SCT-075R-100

What's included with the Magnelab SCT-075R-100

  • Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC, 0.75 inches

Ask a question about Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC, 0.75 inches

Customer Reviews for the Magnelab SCT-075R-100

Magnelab SCT-075R-100 Offers

Magnelab's SCT-075R Series Current Sensors meets ANSI C57.13 revenue grade accuracy class 0.6 with unprecedented linearity and superior phase angle up to 100 Amps passing through the center conductor. Split-core transformers are ideal for installation on electrical wiring by snapping around the conductor. The SCT Series have a self-locking mechanism.

Features

  • Rated input up to 100 Amps
  • Output of 0.333 Volt at rated current
  • Linearity accuracy ± 0.5%
  • Accuracy at 10% to 120% of rated current
  • Phase angle 0.25°
  • 8 ft. twisted-pair lead, 22 AWG
  • Maximum Voltage: 600 V (on bare conductor)
  • UL recognized, CE, and RoHS compliant
  • Other parameters are available at customer request

Magnelab SCT-075R-100 Specifications

Input 100 Amps
Output 0.333 Volt at rated current
Linearity Accuracy ± 0.5%
Accuracy 10% to 120% of rated current
Max. Voltage 600 Volts (on bare conductor)
Click here for complete specifications on the Magnelab SCT-075R-100

What's included with the Magnelab SCT-075R-100

  • Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC, 0.75 inches

Ask a question about Magnelab SCT-075R-100 Revenue Grade Split-Core AC Current Sensor, 100 A, 0.333 VAC, 0.75 inches

Customer Reviews for the Magnelab SCT-075R-100

More Magnelab Products