True RMS, 400A AC/DC, 600V AC/DC, Hz, Power (kW), Phase Rotation, Ohms, Continuity.
True RMS, 400A AC/DC, 600V AC/DC, Hz, Power (kW), Phase Rotation, Ohms, Continuity.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Portable Power Meters category for similar products.
Or let's do a search and help you find what you need:
The AEMC F05 is a high performance clamp-on meter built into a rugged compact sized case, with exceptional ergonomic design and extraordinary measurement possibilities.
Integrating a fast microprocessor sampling at a high rate, the F05 is completely automatic and performs TRMS measurements on the most distorted waveforms. The Model F05 automatically detects AC or DC in Voltage and Current. It has a V-Live™ function to warn of the use of live circuits or elevated voltages. The Model F05 can measure in-rush currents from 1 cycle up to 10 cycles and frequency. It also measures Phase Rotation (using only two leads!), Power Factor and Power. Other features include: auto-ranging, 4000-count display and Auto-Off.
Electrical | |
Measurement Range | 40V: 0.2 to 39.99V / 400V: 40.0 to 399.9V / 4000V: 400 to 600V (400 to 900V pk) |
Accuracy | 40V: 1% of reading + 5cts / 400V: 1% of reading + 2cts / 4000V: 1% of reading + 2cts |
Continuity | |
Measurement Range | 0.0 to 399.9Ω; |
Accuracy | 1% of reading + 2cts |
Resistance | |
Measurement Range | 400Ω: 0.0 to 399.9Ω / 4000Ω: 400 to 3999Ω / 40000Ω: 4.0 to 39.99kΩ; |
Accuracy | 1% of reading + 2cts |
Diode | |
Measurement Range | 4V: 0 to 3.199V |
Current | |
Measurement Range | 40A: 0.20 to 39.99A / 400A: 40 to 399.9A / 4000A: 400 to 600A pk |
Accuracy | 40A: 1.5% of reading + 10cts / 400A: 1.5% of reading + 2cts / 4000A: 1.5% of reading + 2cts |
Resolution | 40A: 10mA / 400A: 100mA / 4000A: 1A |
Inrush Function | |
Range for use | ≥5A pk for the first period of the signal |
Accuracy | 5% + 0.5A |
Capture Time | 0.5 to 10 periods of the signal frequency (8 to 160ms at 60Hz) |
Power | |
Measurement Range | 4kW: 5 to 3999W / 40kW: 4.00 to 39.99kW / 400kW: 40.0 to 240kW |
Power Factor Calculation | |
Measurement Range | 1.00: 0.20 to 0.49 / 0.50 to 1.00 / Accuracy 5% of reading + 2cts / 2% of reading + 2cts |
Frequency | |
Measurement Range | 40Hz: 10.00 to 39.99Hz / 400Hz: 40.0 to 399.9Hz / 4000Hz: 400 to 3999Hz / 40000Hz: 4.00 to 19.99kHz |
Accuracy | 40Hz - 40kHz: 0.4% of reading + 1ct |
General | |
Display | 4 digits, 9999 counts, 3 decimal points, "+" & "-" signs (DC and peak measurement) |
Operating Temperature | 32° to 122°F (0° to 50°C); 90% RH |
Storage Temperature | 40° to 158°F (-40° to 70°C); 90% RH |
Power Source | 9V Alkaline Battery (type IEC 6LF22, 6LR61, or NEDA 1604) |
Jaw Opening | ≤1.00" (≤26mm) |
Dimensions | 2.76 x 7.6 x 1.46" (70 x 193 x 37mm) |
Weight | 9.17 oz (260g) |
Safety | |
Safety Rating | EN62020-1, EN61010-2-032, 600V CAT III |
CE Mark | Yes |
Electrical | |
Measurement Range | 40V: 0.2 to 39.99V / 400V: 40.0 to 399.9V / 4000V: 400 to 600V (400 to 900V pk) |
Accuracy | 40V: 1% of reading + 5cts / 400V: 1% of reading + 2cts / 4000V: 1% of reading + 2cts |
Continuity | |
Measurement Range | 0.0 to 399.9Ω; |
Accuracy | 1% of reading + 2cts |
Resistance | |
Measurement Range | 400Ω: 0.0 to 399.9Ω / 4000Ω: 400 to 3999Ω / 40000Ω: 4.0 to 39.99kΩ; |
Accuracy | 1% of reading + 2cts |
Diode | |
Measurement Range | 4V: 0 to 3.199V |
Current | |
Measurement Range | 40A: 0.20 to 39.99A / 400A: 40 to 399.9A / 4000A: 400 to 600A pk |
Accuracy | 40A: 1.5% of reading + 10cts / 400A: 1.5% of reading + 2cts / 4000A: 1.5% of reading + 2cts |
Resolution | 40A: 10mA / 400A: 100mA / 4000A: 1A |
Inrush Function | |
Range for use | ≥5A pk for the first period of the signal |
Accuracy | 5% + 0.5A |
Capture Time | 0.5 to 10 periods of the signal frequency (8 to 160ms at 60Hz) |
Power | |
Measurement Range | 4kW: 5 to 3999W / 40kW: 4.00 to 39.99kW / 400kW: 40.0 to 240kW |
Power Factor Calculation | |
Measurement Range | 1.00: 0.20 to 0.49 / 0.50 to 1.00 / Accuracy 5% of reading + 2cts / 2% of reading + 2cts |
Frequency | |
Measurement Range | 40Hz: 10.00 to 39.99Hz / 400Hz: 40.0 to 399.9Hz / 4000Hz: 400 to 3999Hz / 40000Hz: 4.00 to 19.99kHz |
Accuracy | 40Hz - 40kHz: 0.4% of reading + 1ct |
General | |
Display | 4 digits, 9999 counts, 3 decimal points, "+" & "-" signs (DC and peak measurement) |
Operating Temperature | 32° to 122°F (0° to 50°C); 90% RH |
Storage Temperature | 40° to 158°F (-40° to 70°C); 90% RH |
Power Source | 9V Alkaline Battery (type IEC 6LF22, 6LR61, or NEDA 1604) |
Jaw Opening | ≤1.00" (≤26mm) |
Dimensions | 2.76 x 7.6 x 1.46" (70 x 193 x 37mm) |
Weight | 9.17 oz (260g) |
Safety | |
Safety Rating | EN62020-1, EN61010-2-032, 600V CAT III |
CE Mark | Yes |