1.800.561.8187

information@ITM.com

Customer Reviews

AEMC L322 4 to 20mA Datalogger

Model: L322 | Order No: 2126.06 | UPC: 685338140378

AEMC L322 4 to 20mA Datalogger-


Downloads:

AEMC L322 4 to 20mA Datalogger

Model: L322 | Order No: 2126.06

2-Channel, 4 to 20mA DC, Current, DataView Software.

2-Channel, 4 to 20mA DC, Current, DataView Software.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

AEMC L452 DC Current/Voltage Data Logger, 100mV/1V/10V DC-

AEMC L452 DC Current/Voltage Data Logger, 100mV/1V/10V DC

Model: L452 | Order No: 2153.51

This Bluetooth-enabled logger and event counter records DC voltage, DC current, and 4 to 20mA pulse counts. Features two input channels that allows the user to connect the Data Logger to various types of sensors as pressure, temperature, flow, humidity, and more.


AEMC Instruments L322 Offers

The AEMC L322 Simple Logger II is a two channel 4-20mADC current data logger. The choice of data storage modes and storage rates allows the operator to effortlessly configure the logger to optimize memory usage to the application at hand. Extended Recording Mode (XRM®) and delayed start time are just two of the many application friendly features.

The AEMC L322 Simple Logger II records DC current at user selectable rates from 125 minutes to 1 day. Current can be measured up to 25mADC with 0.1mA resolution.  The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis

Applications:

  • Process control monitoring and troubleshooting
  • Sensor monitoring
  • General DC current monitoring
  • Profile temperature, pressure, flow and other parameters directly

AEMC Instruments L322 Specifications

Simple Logger II Model L322
Electrical
Channels Two
Input Connection Detachable terminal strip
Measurement Range 0 to 25mAdc
Resolution 0.1mA
Accuracy (DC and 50/60Hz) 0 to 1mA: unspecified 1mA to 30mA: ±(0.25% of Reading + 100µA)
Sample Rate 8 samples taken at storage interval
Storage Rate Programmable from 125ms to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell alkaline batteries
Battery Life 100 hours to >45 days (dependent on sample rate and recording length)
Mechanical
Dimensions 5.43 x 2.75 x 1.28" (138 x 70 x 32mm)
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Click here for complete specifications on the AEMC Instruments L322

What's included with the AEMC Instruments L322

  • AEMC L322 4 to 20mA Datalogger

Ask a question about AEMC L322 4 to 20mA Datalogger

Customer Reviews for the AEMC Instruments L322

AEMC Instruments L322 Offers

The AEMC L322 Simple Logger II is a two channel 4-20mADC current data logger. The choice of data storage modes and storage rates allows the operator to effortlessly configure the logger to optimize memory usage to the application at hand. Extended Recording Mode (XRM®) and delayed start time are just two of the many application friendly features.

The AEMC L322 Simple Logger II records DC current at user selectable rates from 125 minutes to 1 day. Current can be measured up to 25mADC with 0.1mA resolution.  The main advantage of the logger is its ability to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView® software.

Analog information on the input is sampled and converted to a digital signal. This digital signal is processed and stored along with scale and time information. An optically isolated Universal Serial Bus (USB) port provides for the transfer of data from the instrument’s internal memory to the computer for analysis

Applications:

  • Process control monitoring and troubleshooting
  • Sensor monitoring
  • General DC current monitoring
  • Profile temperature, pressure, flow and other parameters directly

AEMC Instruments L322 Specifications

Simple Logger II Model L322
Electrical
Channels Two
Input Connection Detachable terminal strip
Measurement Range 0 to 25mAdc
Resolution 0.1mA
Accuracy (DC and 50/60Hz) 0 to 1mA: unspecified 1mA to 30mA: ±(0.25% of Reading + 100µA)
Sample Rate 8 samples taken at storage interval
Storage Rate Programmable from 125ms to 1 day
Storage Modes Start/Stop, FIFO and Extended Recording Mode (XRM)
Recording Length 15 minutes to 8 weeks, programmable using DataView
Memory 240,000 measurements (512KB) The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed.
Communication USB 2.0 optically isolated
Power Source 2 x 1.5V AA-cell alkaline batteries
Battery Life 100 hours to >45 days (dependent on sample rate and recording length)
Mechanical
Dimensions 5.43 x 2.75 x 1.28" (138 x 70 x 32mm)
Weight (with battery) 6.4 oz (181 grams)
Case UL94-V0
Vibration IEC 68-2-6 (1.5mm, 10 to 55Hz)
Shock IEC 68-2-27 (30G)
Drop IEC 68-2-32 (1m)
Click here for complete specifications on the AEMC Instruments L322

What's included with the AEMC Instruments L322

  • AEMC L322 4 to 20mA Datalogger

Ask a question about AEMC L322 4 to 20mA Datalogger

Customer Reviews for the AEMC Instruments L322

More AEMC Instruments Products