Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface

Model: ES2101AE

Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface-


Downloads: datasheet

Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface

Model: ES2101AE

This permanently installed, stand-alone 3.78 x 3.78in (96 x 96mm) panel meter measures more than 60 parameters, enabling you to monitor energy consumption on a continuous basis. The panel meter has a 1A power rating and an Ethernet interface.

This permanently installed, stand-alone 3.78 x 3.78in (96 x 96mm) panel meter measures more than 60 parameters, enabling you to monitor energy consumption on a continuous basis. The panel meter has a 1A power rating and an Ethernet interface.

Regular Price $1744.00 CAD
Availability 2 to 3 Weeks
Quantity

Dranetz ES2101AE Offers



Features

  • Measures more than 60 parameters, including true RMS voltage and current, kW, kVA, KVAR, power factor and frequency
  • DIN96, 3.78 x 3.78 x 1.81in (96 x 96 x 46mm), ABS plastic panel-mount enclosure
  • Ethernet interface means the DataNode® can be used with web browser-based Encore Series Software for remote access to real time and recorded data
  • Aggregated Energy Expense – Usage and cost for all DataNodes® or monitoring instruments for a given time period
  • Energy Expense – Energy use for a particular DataNode® for a specific time period compared to rate structure
  • Energy Usage Comparison – Energy use for a specific monitoring location for various time periods against a specified reference period
  • Input Data - Accepts energy usage and demand data from any DataNode®; user must input rate structures and peak/off-peak consumption and demand parameters
  • Output information - On-peak energy consumption in $kWHr, $/kW and $/kVARHr; partial-peak energy consumption in $kWHr, $/kW and $/kVARHr; off-peak energy consumption in $/kWHr, $/kW and $/kVARHr
  • Algorithms - Algorithms for usage comparison with rate, time, peak, penalty and tax

Applications

Track Power and Energy Costs

Reducing consumption during peak times or shifting loads to off-peak times can save a typical commercial or industrial facility from 10 to 50% annually on energy costs. By monitoring energy consumption on a continuous basis using the ES Series DataNode®, energy and demand data can be gathered for an entire facility and at key consumption points, including energy-intensive processes and key machinery. The ES Series DataNode® is part of Encore® Series Software, which automatically plots and trends this data to develop daily, weekly, monthly or yearly load profiles. Encore® Series Software can also alert the user to shed loads before a new demand level is reached. The available Energy Usage Answer Module® enables Encore® Series Software to aggregate energy from multiple points, compute costing information and provide other advanced energy reports. This information can be reconciled with operating data from other systems, including building automation and process control, to understand how variations in facility operations affect the load profile and electricity bill.

Facilities armed with load profile data are better positioned to negotiate energy purchase contracts. Data from the ES Series DataNode® can be used to develop a price/risk curve for evaluating options such as fixed, time-of-use and real-time pricing plans. Without this data, a facility might incur much higher energy or peak-demand charges than necessary or carry more than the appropriate level of risk.

Evaluate Energy Reduction Strategies

When and where electricity is consumed is invaluable information to have when developing energy reduction strategies, which can include lighting upgrades, HVAC/R replacement, installation of high efficiency motors and/or adjustable speed drives and other cost-saving measures. The data provided by the ES Series DataNode® arms the user with the information necessary to understand your facility, its loads and energy usage profile. This information, combined with your local utility rate structure, enables you to intelligently target areas of your facility in order to provide the best return on your energy reduction budget. Not only can you reduce your overall energy usage, but utility charges, such as power factor penalties and time of use demand penalties, can be targeted for reduction by mitigating such problems or shifting loads to less expensive times of the day.

Protect Your Infrastructure

The system software, Encore® Software, automatically collects data from all instruments in your monitoring system in an easy-to-use, web browser-based operating environment, allowing multiple users to simultaneously see data in real time, trend historical information, produce reports and even intelligently analyze data using the unique Answer Modules®. Whether your application requires demand and energy monitoring, power quality monitoring or both, Dranetz Encore® System can meet your fixed system needs.

Encore® Software

Encore® Software is a web-based, advanced, intelligent software that is both a system controller and a user interface for your entire system. Encore® Software can be used in any application, from small systems with a few instruments to very large multi-point, facility-wide or utility monitoring systems with 50 or more points. Encore® Software automatically communicates with each instrument in your system via all supported communications methods to download and store data. Encore® Software is also a password-protected web server that acts as the gateway to your Encore® System. All user interactions with the system, such as trending, reports, real-time and setups, are done using a web browser with connectivity to the system. The multi-user interface allows co-workers, engineers or consultants to analyze and share data and reports within a familiar web environment with simultaneous access.

Answer Modules® - Save Time and Improve Accuracy When Troubleshooting

Answer Modules® are proprietary algorithms that convert raw power quality event data into precise answers to determine the source and cause of the disturbance. These unique tools enable users to save time and improve accuracy when troubleshooting power quality problems.

Answer Modules® Available for Encore® Series Software

  • Sag Directivity SW Module: SW-SAG
  • PF Cap Directivity Answer Module: SW-PFCAP
  • UPS Verification SW Module: SW-UPS
  • Dranetz ES2101AE Specifications

    Measurements 60+ parameters, including true RMS voltage and current, kVA, kVAR, kW, PF, frequency, kWh and demand
    Voltage Single phase, 3-phase, 500VAC L-L or 290VAC L-N, 50/60Hz, 0.5% accuracy; screw terminals
    Current 1A nominal, 0.5% accuracy; screw terminals
    Communications 10/100baseT Ethernet (RJ45), Modbus TCP
    Instrument Power 85 to 253V AC/DC, 45 to 400Hz, <3VA (without extension module); screw terminals
    Enclosure DIN96, 3.78 x 3.78 x 1.81in (96 x 96 x 46mm), ABS plastic
    Display 0.55in (14mm) red LED digital display, adjustable brightness; number of digits: measured values, 4 digits with sign; energy counters: 8 digits (top and middle display)
    Safety and Compliance CE, IEC1010, EN61010; Protection Class II; enclosure protection: front IP66, terminals IP20
    Click here for complete specifications on the Dranetz ES2101AE

    What's included with the Dranetz ES2101AE

    • Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface

    The Fundamentals of Power Monitoring with Dranetz


    In this informative webinar we focused on the fundamentals of power monitoring and the importance of implementing some form of energy management control because “you cannot manage what you cannot measure”, with the ultimate goal of improving energy efficiency. <br /><br />This webinar addresses the following issues:<ul><li> The distinction between power measuring and monitoring</li><li> The difference between energy and power quality</li><li> The pros and cons of portable or permanent/fixed solutions</li><li> The benefits of power monitoring</li><li> The basics of AC electric power and power quality</li><li> The differences between energy and demand</li><li> The types of power quality disturbances, their sources and measurement standards</li></ul>

    Accessories

    Click on a category to view a selection of compatible accessories with the Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface.

    Dranetz ES230 RS-232 Interface Cable for ES2 Encore Series Energy DataNodes ES230RS232
    This RS-232 interface cable can be used with your ES2 Encore Series Energy DataNodes to analyze and manage data consumption.
    $47.32 CAD

    was $56.00


    Learn More

    Ask a question about Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface

    Customer Reviews for the Dranetz ES2101AE

    Dranetz ES2101AE Offers

    

    Features

    • Measures more than 60 parameters, including true RMS voltage and current, kW, kVA, KVAR, power factor and frequency
    • DIN96, 3.78 x 3.78 x 1.81in (96 x 96 x 46mm), ABS plastic panel-mount enclosure
    • Ethernet interface means the DataNode® can be used with web browser-based Encore Series Software for remote access to real time and recorded data
    • Aggregated Energy Expense – Usage and cost for all DataNodes® or monitoring instruments for a given time period
    • Energy Expense – Energy use for a particular DataNode® for a specific time period compared to rate structure
    • Energy Usage Comparison – Energy use for a specific monitoring location for various time periods against a specified reference period
    • Input Data - Accepts energy usage and demand data from any DataNode®; user must input rate structures and peak/off-peak consumption and demand parameters
    • Output information - On-peak energy consumption in $kWHr, $/kW and $/kVARHr; partial-peak energy consumption in $kWHr, $/kW and $/kVARHr; off-peak energy consumption in $/kWHr, $/kW and $/kVARHr
    • Algorithms - Algorithms for usage comparison with rate, time, peak, penalty and tax

    Applications

    Track Power and Energy Costs

    Reducing consumption during peak times or shifting loads to off-peak times can save a typical commercial or industrial facility from 10 to 50% annually on energy costs. By monitoring energy consumption on a continuous basis using the ES Series DataNode®, energy and demand data can be gathered for an entire facility and at key consumption points, including energy-intensive processes and key machinery. The ES Series DataNode® is part of Encore® Series Software, which automatically plots and trends this data to develop daily, weekly, monthly or yearly load profiles. Encore® Series Software can also alert the user to shed loads before a new demand level is reached. The available Energy Usage Answer Module® enables Encore® Series Software to aggregate energy from multiple points, compute costing information and provide other advanced energy reports. This information can be reconciled with operating data from other systems, including building automation and process control, to understand how variations in facility operations affect the load profile and electricity bill.

    Facilities armed with load profile data are better positioned to negotiate energy purchase contracts. Data from the ES Series DataNode® can be used to develop a price/risk curve for evaluating options such as fixed, time-of-use and real-time pricing plans. Without this data, a facility might incur much higher energy or peak-demand charges than necessary or carry more than the appropriate level of risk.

    Evaluate Energy Reduction Strategies

    When and where electricity is consumed is invaluable information to have when developing energy reduction strategies, which can include lighting upgrades, HVAC/R replacement, installation of high efficiency motors and/or adjustable speed drives and other cost-saving measures. The data provided by the ES Series DataNode® arms the user with the information necessary to understand your facility, its loads and energy usage profile. This information, combined with your local utility rate structure, enables you to intelligently target areas of your facility in order to provide the best return on your energy reduction budget. Not only can you reduce your overall energy usage, but utility charges, such as power factor penalties and time of use demand penalties, can be targeted for reduction by mitigating such problems or shifting loads to less expensive times of the day.

    Protect Your Infrastructure

    The system software, Encore® Software, automatically collects data from all instruments in your monitoring system in an easy-to-use, web browser-based operating environment, allowing multiple users to simultaneously see data in real time, trend historical information, produce reports and even intelligently analyze data using the unique Answer Modules®. Whether your application requires demand and energy monitoring, power quality monitoring or both, Dranetz Encore® System can meet your fixed system needs.

    Encore® Software

    Encore® Software is a web-based, advanced, intelligent software that is both a system controller and a user interface for your entire system. Encore® Software can be used in any application, from small systems with a few instruments to very large multi-point, facility-wide or utility monitoring systems with 50 or more points. Encore® Software automatically communicates with each instrument in your system via all supported communications methods to download and store data. Encore® Software is also a password-protected web server that acts as the gateway to your Encore® System. All user interactions with the system, such as trending, reports, real-time and setups, are done using a web browser with connectivity to the system. The multi-user interface allows co-workers, engineers or consultants to analyze and share data and reports within a familiar web environment with simultaneous access.

    Answer Modules® - Save Time and Improve Accuracy When Troubleshooting

    Answer Modules® are proprietary algorithms that convert raw power quality event data into precise answers to determine the source and cause of the disturbance. These unique tools enable users to save time and improve accuracy when troubleshooting power quality problems.

    Answer Modules® Available for Encore® Series Software

  • Sag Directivity SW Module: SW-SAG
  • PF Cap Directivity Answer Module: SW-PFCAP
  • UPS Verification SW Module: SW-UPS
  • Dranetz ES2101AE Specifications

    Measurements 60+ parameters, including true RMS voltage and current, kVA, kVAR, kW, PF, frequency, kWh and demand
    Voltage Single phase, 3-phase, 500VAC L-L or 290VAC L-N, 50/60Hz, 0.5% accuracy; screw terminals
    Current 1A nominal, 0.5% accuracy; screw terminals
    Communications 10/100baseT Ethernet (RJ45), Modbus TCP
    Instrument Power 85 to 253V AC/DC, 45 to 400Hz, <3VA (without extension module); screw terminals
    Enclosure DIN96, 3.78 x 3.78 x 1.81in (96 x 96 x 46mm), ABS plastic
    Display 0.55in (14mm) red LED digital display, adjustable brightness; number of digits: measured values, 4 digits with sign; energy counters: 8 digits (top and middle display)
    Safety and Compliance CE, IEC1010, EN61010; Protection Class II; enclosure protection: front IP66, terminals IP20
    Click here for complete specifications on the Dranetz ES2101AE

    What's included with the Dranetz ES2101AE

    • Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface

    The Fundamentals of Power Monitoring with Dranetz


    In this informative webinar we focused on the fundamentals of power monitoring and the importance of implementing some form of energy management control because “you cannot manage what you cannot measure”, with the ultimate goal of improving energy efficiency. <br /><br />This webinar addresses the following issues:<ul><li> The distinction between power measuring and monitoring</li><li> The difference between energy and power quality</li><li> The pros and cons of portable or permanent/fixed solutions</li><li> The benefits of power monitoring</li><li> The basics of AC electric power and power quality</li><li> The differences between energy and demand</li><li> The types of power quality disturbances, their sources and measurement standards</li></ul>

    Accessories

    Click on a category to view a selection of compatible accessories with the Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface.

    Dranetz ES230 RS-232 Interface Cable for ES2 Encore Series Energy DataNodes ES230RS232
    This RS-232 interface cable can be used with your ES2 Encore Series Energy DataNodes to analyze and manage data consumption.
    $47.32 CAD

    was $56.00


    Learn More

    Ask a question about Dranetz ES2101AE Energy DataNode DIN96 Panel Meter, 1A, Ethernet Interface

    Customer Reviews for the Dranetz ES2101AE

    More Dranetz Products