Comes with a single channel, the instrumentation logger features a 60,000 data set/channel memory to measure instrumentation signals. It logs instrumentation signals such as 4 to 20 mA signals over 1 channel in as fast as 1-second intervals. It has a measurement range of -30 to 30 mA.
Comes with a single channel, the instrumentation logger features a 60,000 data set/channel memory to measure instrumentation signals. It logs instrumentation signals such as 4 to 20 mA signals over 1 channel in as fast as 1-second intervals. It has a measurement range of -30 to 30 mA.
Offers 4 to 20 mA DC measurements.
Features
Applications
| Measurement Range | -30 to 30 mA |
| Basic Accuracy | ±0.5 %rdg. ±5 dgt. |
| Storage Capacity | Instantaneous value mode: 60,000 data/ch, statistical value mode: 15,000 data/ch |
| Recording Interval | 1 to 30 sec., 1 to 60 min., 15 selections |
| Recording Modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
| Recording Methods | One-time recording: stop recording when the memory capacity is full Endless recording: continue recording even when the memory capacity is full (old data is overwritten) Start: logger button operation or scheduled time Stop: logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
| Other Functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approximately 30 sec. of recording operation and clock while battery is replaced |
| Waterproof and Dust-proof | IP54 (EN60529), with sensor connected, but not including sensor tip |
| Interfaces | Infrared optical communications with LR5091, LR5092-20 |
| Power Supply | Type: LR6 (AA) alkaline battery x 1 Life: approximately 3 months |
| Dimensions | 3.11 x 2.246 x 1.1" (79 x 57 x 28 mm) |
| Mass | 105 g (3.7 oz) |
| Measurement Range | -30 to 30 mA |
| Basic Accuracy | ±0.5 %rdg. ±5 dgt. |
| Storage Capacity | Instantaneous value mode: 60,000 data/ch, statistical value mode: 15,000 data/ch |
| Recording Interval | 1 to 30 sec., 1 to 60 min., 15 selections |
| Recording Modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
| Recording Methods | One-time recording: stop recording when the memory capacity is full Endless recording: continue recording even when the memory capacity is full (old data is overwritten) Start: logger button operation or scheduled time Stop: logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
| Other Functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low; guarantees approximately 30 sec. of recording operation and clock while battery is replaced |
| Waterproof and Dust-proof | IP54 (EN60529), with sensor connected, but not including sensor tip |
| Interfaces | Infrared optical communications with LR5091, LR5092-20 |
| Power Supply | Type: LR6 (AA) alkaline battery x 1 Life: approximately 3 months |
| Dimensions | 3.11 x 2.246 x 1.1" (79 x 57 x 28 mm) |
| Mass | 105 g (3.7 oz) |