Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet

Model: A7810-000 | UPC: 07847761260

Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet-


Downloads: datasheet manual

Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet

Model: A7810-000

The Leviton A7810-000 Energy Monitoring HUB is an intelligent, flexible data acquisition server allowing users to collect energy data from pulse output meters through 4 pulse inputs. Designed to connect to IP-based applications such as enterprise energy management, demand response and smart grid programs, the EMB HubLite server lets you benchmark energy usage and reduce energy costs. Power supply not included.

The Leviton A7810-000 Energy Monitoring HUB is an intelligent, flexible data acquisition server allowing users to collect energy data from pulse output meters through 4 pulse inputs. Designed to connect to IP-based applications such as enterprise energy management, demand response and smart grid programs, the EMB HubLite server lets you benchmark energy usage and reduce energy costs. Power supply not included.

Discontinued!

This product has been discontinued and is no longer available.

There is no direct replacement, however we recommend the:

Obvius A7810-0 (4 pulse inputs, Ethernet), DIN or Wall Mount, UL, CE-

Obvius A7810-0 (4 pulse inputs, Ethernet), DIN or Wall Mount, UL, CE

Model: A7810-0

Ideal for collecting pulse outputs from various utility meters and submeters. Connect up to four pulse meters to start logging and viewing data through any web browser.

The replacement product is only available on our affiliate ITM.com website. Don't worry your cart and information will be brought over.


Not what you're looking for? Let’s do a search and help you find what you need.


Leviton A7810-000 Offers

Features

  • Push or pull meter data to energy dashboards, kiosks and software applications
  • Create load profiles for energy purchases
  • Utility submetering (electricity, gas, water, etc.)
  • Measurement and verification (M&V)
  • Access energy information from local or remote sites
  • Benchmark building energy usage
  • View "real time" performance data
  • Track energy use and peak demand for Demand Response programs
  • Monitor utility meters for rebate program compliance
  • Alarm notification for data points above or below target levels (including SNMP Traps)
  • LEED / Energy Star certification

Leviton A7810-000 Specifications

Processor ARM 9 embedded CPU
Operating System Linux 2.6
Memory 32 MB RAM
Flash ROM 16 MB NOR Flash
Interval Recording 1 to 60 minutes, user selectable (default 15 minutes)
LEDs Ethernet, Pulse (x4), power, alarm
Console 2 x 16 LCD character, two push buttons
Power
Power Supply 24VDC, 500mA, Required (not included) *This unit is to be sourced by a Class 2 power supply with the following output: 24VDC, 500mA min not to exceed 8A. Note: Only 350mA is required if the USB port is not used.
Isolation RJ45 Ethernet is isolated to 1500VDC from the main board. (Power input, Pulse inputs and USB nonisolated)
Communication
Protocols Modbus/TCP, TCP/IP, PPP, HTTP/HTML, FTP, NTP, XML, SNMP-Trap
LAN RJ45 10/100 Ethernet, full/half duplex, auto polarity
USB USB expansion port (cellular modem options available)
Inputs
I/O 4x Pulse inputs, dry contact, standard or KYZ, closure threshold 100 to 2.5K user selectable
Pulse Rate Pulse input maximum rate 10Hz, minimum pulse width 50ms
Storage Pulse count values stored in non-volatile memory
Physical
Weight 0.42lbs (0.19g)
Size 4 x 4.25 x 2" (102 x 108 x 51mm)
Environment
North America -30 to 70°C, 0 to 95% RH, Non-Condensing
Altitude 2000M max
Pollution Degree 2
Codes and Standards
Emissions FCC CFR 47 Part 15, Class A, EN 61000, EN61326
Safety UL61010 Recognized, EN 61010
Click here for complete specifications on the Leviton A7810-000

What's included with the Leviton A7810-000

  • Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet

Ask a question about Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet

Customer Reviews for the Leviton A7810-000

Leviton A7810-000 Offers

Features

  • Push or pull meter data to energy dashboards, kiosks and software applications
  • Create load profiles for energy purchases
  • Utility submetering (electricity, gas, water, etc.)
  • Measurement and verification (M&V)
  • Access energy information from local or remote sites
  • Benchmark building energy usage
  • View "real time" performance data
  • Track energy use and peak demand for Demand Response programs
  • Monitor utility meters for rebate program compliance
  • Alarm notification for data points above or below target levels (including SNMP Traps)
  • LEED / Energy Star certification

Leviton A7810-000 Specifications

Processor ARM 9 embedded CPU
Operating System Linux 2.6
Memory 32 MB RAM
Flash ROM 16 MB NOR Flash
Interval Recording 1 to 60 minutes, user selectable (default 15 minutes)
LEDs Ethernet, Pulse (x4), power, alarm
Console 2 x 16 LCD character, two push buttons
Power
Power Supply 24VDC, 500mA, Required (not included) *This unit is to be sourced by a Class 2 power supply with the following output: 24VDC, 500mA min not to exceed 8A. Note: Only 350mA is required if the USB port is not used.
Isolation RJ45 Ethernet is isolated to 1500VDC from the main board. (Power input, Pulse inputs and USB nonisolated)
Communication
Protocols Modbus/TCP, TCP/IP, PPP, HTTP/HTML, FTP, NTP, XML, SNMP-Trap
LAN RJ45 10/100 Ethernet, full/half duplex, auto polarity
USB USB expansion port (cellular modem options available)
Inputs
I/O 4x Pulse inputs, dry contact, standard or KYZ, closure threshold 100 to 2.5K user selectable
Pulse Rate Pulse input maximum rate 10Hz, minimum pulse width 50ms
Storage Pulse count values stored in non-volatile memory
Physical
Weight 0.42lbs (0.19g)
Size 4 x 4.25 x 2" (102 x 108 x 51mm)
Environment
North America -30 to 70°C, 0 to 95% RH, Non-Condensing
Altitude 2000M max
Pollution Degree 2
Codes and Standards
Emissions FCC CFR 47 Part 15, Class A, EN 61000, EN61326
Safety UL61010 Recognized, EN 61010
Click here for complete specifications on the Leviton A7810-000

What's included with the Leviton A7810-000

  • Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet

Ask a question about Leviton A7810-000 Energy Monitoring HUB EMB Lite, 4 Pulse Inputs, Ethernet

Customer Reviews for the Leviton A7810-000

More Leviton Products