The single-circuit, DIN-mounted energy meter with watt-hours pulse, VAR-hours pulse and alarm outputs is for use with series rope-style CTs. Complete with data logging: 3 time-stamped 32-bit configurable data buffers.
The single-circuit, DIN-mounted energy meter with watt-hours pulse, VAR-hours pulse and alarm outputs is for use with series rope-style CTs. Complete with data logging: 3 time-stamped 32-bit configurable data buffers.
Discontinued!
This product has been discontinued and is no longer available.
There is no direct replacement, however we recommend the:
The replacement product is only available on our affiliate ITM.com website. Don't worry your cart and information will be brought over.
Not what you're looking for? Let’s do a search and help you find what you need.
The single-circuit, DIN-mounted energy meter with watt-hours pulse, VAR-hours pulse and alarm outputs is for use with series rope-style CTs. Complete with data logging: 3 time-stamped 32-bit configurable data buffers.
Features
Applications
| Real Power and Energy | 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5S) |
| Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
| Control Power, DC | 3 W max.; UL and CE: 125 to 300 VDC (external DC current limiting required) |
| Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
| Current Input | 50 to 5,000 A |
| Scaling Input Range | E683x series rope-style CTs only (CTs must be rated for connection to Class 1 voltage inputs) |
| Pulse Inputs (E5xHxA and E50FxA only) | Contact inputs to pulse accumulators (1 set with E5xH2A & E50F2A; 2 sets with E5xH5A & E51F5A) |
| Operating Temperature Range | -22 to 158°F (-30 to 70°C) |
| Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
| Humidity Range | <95% RH non-condensing |
| Mounting Location | Not suitable for wet locations; for indoor use only |
| Warranty | 5 years limited |
| Agency Approvals | UL 508, IEC/EN 61010-1, California CSI Solar, ANSI C12.20 |
| Real Power and Energy | 0.5% (ANSI C12.20, IEC 62053-22 Class 0.5S) |
| Control Power, AC | 50/60 Hz; 5 VA max.; 90 V min.; UL Maximums: 600 V L-L (347 V L-N); CE Maximum: 300 V L-N |
| Control Power, DC | 3 W max.; UL and CE: 125 to 300 VDC (external DC current limiting required) |
| Voltage Input | UL: 90 V L-N to 600 V L-L; CE: 90 V L-N to 300 V L-N |
| Current Input | 50 to 5,000 A |
| Scaling Input Range | E683x series rope-style CTs only (CTs must be rated for connection to Class 1 voltage inputs) |
| Pulse Inputs (E5xHxA and E50FxA only) | Contact inputs to pulse accumulators (1 set with E5xH2A & E50F2A; 2 sets with E5xH5A & E51F5A) |
| Operating Temperature Range | -22 to 158°F (-30 to 70°C) |
| Storage Temperature Range | -40 to 185°F (-40 to 85°C) |
| Humidity Range | <95% RH non-condensing |
| Mounting Location | Not suitable for wet locations; for indoor use only |
| Warranty | 5 years limited |
| Agency Approvals | UL 508, IEC/EN 61010-1, California CSI Solar, ANSI C12.20 |