Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS

Model: H8437VBS

Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS-


Downloads: datasheet

Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS

Model: H8437VBS

The single-circuit, panel-mounted digital power meter delivers high accuracy and high value with 1 V CT input.

The single-circuit, panel-mounted digital power meter delivers high accuracy and high value with 1 V CT input.

Discontinued!

This product has been discontinued and is no longer available. There are no replacement options.

We can help you find what you need:


Veris H8437VBS Offers

The single-circuit, panel-mounted digital power meter delivers high accuracy and high value with 1 V CT input.

Features

  • Multiple values displayed at the same time on an anti-glare display featuring a green backlight
  • Digital power meters automatically detect and correct phase reversal, eliminating the need to be concerned with CT load orientation
  • 1% energy and power accuracy

Applications

  • Energy Managing and Performance Contracting
  • Submetering for Commercial Tenants
  • Activity-Based Costing in Commercial and Industrial Facilities
  • Real-Time Power Monitoring via Local Display or Through Control/Data Acquisition Systems

Veris H8437VBS Specifications

Input Voltage Measured UL 600 VAC (L-L); CE 300 VAC (L-N); metering over-range: +20%; impedance: 2 MO (L-L) / 1 MO (L-N); frequency range: 45 to 65 Hz
Electrical Measurement: True RMS up to the 15th harmonic, 3-phase AC system
Data Update Rate 1 second
Measurement Accuracy Current and voltage: ANSI C12.16, 0.5%; power: ANSI C12.16, 1%; frequency: ±0.01 Hz from 45 to 65 Hz
Current Input CT scaling primary: adjustable from 5 to 32,767 A; measurement input range: 1 V RMS full scale (+20% over-range)
Impedance 100 kO
Control Power AC 100 to 415 ±10% VAC, 5 VA; DC125 to 250 ±20% VDC, 3 W; ride-through time 100 ms at 120 VAC
Pulse Output #1 N.O. static output (240 VAC or 300 VDC, 100 mA max at 25°C, derate 0.56 mA per °C above 25°C), 2.41 kV RMS isolation
Pulse Output #2 H8453V/VB/VBS (phase loss or kVARh) N.O., static output (240 VAC or 300 VDC, 100 mA max at 25°C, derate 0.56 mA per °C above 25°C) 2.41 kV RMS isolation
Communication RS-485 port; H8436V/VB/VBS; H8437V/VB/VBS 2-wire, 2400 to 19200 baud, Modbus RTU
Weight H8400V = 0.81 lb; H8400VB = 6.35 lbs; H8400VBS = 9.15 lbs
Protection Class VB: NEMA 1, IP40; V: IP50 front, IP30 back
Operating Temperature Meter: 32 to 140°F (0 to 60°C); display: 14 to 122°F (-10 to 50°C)
Storage Temperature -40 to 185°F (-40 to 85°C) meter and display
Humidity Range 5 to 95% RH at 122°F (50°C), non-condensing
Approval North America (UL) CAT III Pollution Degree 2, for distribution systems up to 347 VAC L-N/600VAC L-L; Europe (CE) CAT III Pollution Degree 2; for distribution systems up to 300 VAC L-N/480VAC L-L; dielectric withstand per UL 508, EN61010; Conducted & Radiated Emissions FCC part 15 EN55011/EN6100 Class B**; Conducted & Radiated Immunity EN6100 Class A***
Safety North America (cULus) UL508/C22.2; Europe (CE) CE per IEC 61010
Display 2.9 x 2.7" (73 x 69 mm) backlit green LCD (6 lines total, 4 concurrent values)
Click here for complete specifications on the Veris H8437VBS

What's included with the Veris H8437VBS

  • Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS

Ask a question about Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS

Customer Reviews for the Veris H8437VBS

Veris H8437VBS Offers

The single-circuit, panel-mounted digital power meter delivers high accuracy and high value with 1 V CT input.

Features

  • Multiple values displayed at the same time on an anti-glare display featuring a green backlight
  • Digital power meters automatically detect and correct phase reversal, eliminating the need to be concerned with CT load orientation
  • 1% energy and power accuracy

Applications

  • Energy Managing and Performance Contracting
  • Submetering for Commercial Tenants
  • Activity-Based Costing in Commercial and Industrial Facilities
  • Real-Time Power Monitoring via Local Display or Through Control/Data Acquisition Systems

Veris H8437VBS Specifications

Input Voltage Measured UL 600 VAC (L-L); CE 300 VAC (L-N); metering over-range: +20%; impedance: 2 MO (L-L) / 1 MO (L-N); frequency range: 45 to 65 Hz
Electrical Measurement: True RMS up to the 15th harmonic, 3-phase AC system
Data Update Rate 1 second
Measurement Accuracy Current and voltage: ANSI C12.16, 0.5%; power: ANSI C12.16, 1%; frequency: ±0.01 Hz from 45 to 65 Hz
Current Input CT scaling primary: adjustable from 5 to 32,767 A; measurement input range: 1 V RMS full scale (+20% over-range)
Impedance 100 kO
Control Power AC 100 to 415 ±10% VAC, 5 VA; DC125 to 250 ±20% VDC, 3 W; ride-through time 100 ms at 120 VAC
Pulse Output #1 N.O. static output (240 VAC or 300 VDC, 100 mA max at 25°C, derate 0.56 mA per °C above 25°C), 2.41 kV RMS isolation
Pulse Output #2 H8453V/VB/VBS (phase loss or kVARh) N.O., static output (240 VAC or 300 VDC, 100 mA max at 25°C, derate 0.56 mA per °C above 25°C) 2.41 kV RMS isolation
Communication RS-485 port; H8436V/VB/VBS; H8437V/VB/VBS 2-wire, 2400 to 19200 baud, Modbus RTU
Weight H8400V = 0.81 lb; H8400VB = 6.35 lbs; H8400VBS = 9.15 lbs
Protection Class VB: NEMA 1, IP40; V: IP50 front, IP30 back
Operating Temperature Meter: 32 to 140°F (0 to 60°C); display: 14 to 122°F (-10 to 50°C)
Storage Temperature -40 to 185°F (-40 to 85°C) meter and display
Humidity Range 5 to 95% RH at 122°F (50°C), non-condensing
Approval North America (UL) CAT III Pollution Degree 2, for distribution systems up to 347 VAC L-N/600VAC L-L; Europe (CE) CAT III Pollution Degree 2; for distribution systems up to 300 VAC L-N/480VAC L-L; dielectric withstand per UL 508, EN61010; Conducted & Radiated Emissions FCC part 15 EN55011/EN6100 Class B**; Conducted & Radiated Immunity EN6100 Class A***
Safety North America (cULus) UL508/C22.2; Europe (CE) CE per IEC 61010
Display 2.9 x 2.7" (73 x 69 mm) backlit green LCD (6 lines total, 4 concurrent values)
Click here for complete specifications on the Veris H8437VBS

What's included with the Veris H8437VBS

  • Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS

Ask a question about Veris H8437VBS Single-Circuit Digital Power Meter for voltage-mode CTs, 240 to 600 V, FDS

Customer Reviews for the Veris H8437VBS

More Veris Products