Veris H932 Current Monitoring Current Transducer with relay, 0 to 5 VDC analog output

Model: H932

Veris H932 Current Monitoring Current Transducer with relay, 0 to 5 VDC analog output-


Downloads: datasheet

Veris H932 Current Monitoring Current Transducer with relay, 0 to 5 VDC analog output

Model: H932

The current transducer with relay provides accurate load trending information with a proportional 0 to 5 VDC output signal. And with an integrated command relay, this product is ideal for the start/stop and status monitoring of motors.

The current transducer with relay provides accurate load trending information with a proportional 0 to 5 VDC output signal. And with an integrated command relay, this product is ideal for the start/stop and status monitoring of motors.

Sale Price $169.00 CAD
Regular Price $334.19 CAD
Availability 2 to 3 Weeks
Quantity

Veris H932 Offers

The current transducer with relay provides accurate load trending information with a proportional 0 to 5 VDC output signal. And with an integrated command relay, this product is ideal for the start/stop and status monitoring of motors.

Features

  • Reduces the number of installed components to save time and space
  • Self-gripping split-core for fast retrofit installation; no need to remove conductor
  • 1 device to install for start/stop and status, which reduces installation charges
  • Factory calibrated switch-selectable ranges (30/60/120 A) for high resolution and installation ease
  • No jumpers on unit to help reduce installation error
  • Bracket can be installed in 3 different configurations for added flexibility
  • Command relay switches up to 5 A at 250 VAC
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Fan/Pump Status

Veris H932 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 600 VAC RMS
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm²)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Warranty 5 years limited
Agency Approvals UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation
Click here for complete specifications on the Veris H932

What's included with the Veris H932

  • Veris H932 Current Monitoring Current Transducer with relay, 0 to 5 VDC analog output

Ask a question about Veris H932 Current Monitoring Current Transducer with relay, 0 to 5 VDC analog output

Customer Reviews for the Veris H932

Veris H932 Offers

The current transducer with relay provides accurate load trending information with a proportional 0 to 5 VDC output signal. And with an integrated command relay, this product is ideal for the start/stop and status monitoring of motors.

Features

  • Reduces the number of installed components to save time and space
  • Self-gripping split-core for fast retrofit installation; no need to remove conductor
  • 1 device to install for start/stop and status, which reduces installation charges
  • Factory calibrated switch-selectable ranges (30/60/120 A) for high resolution and installation ease
  • No jumpers on unit to help reduce installation error
  • Bracket can be installed in 3 different configurations for added flexibility
  • Command relay switches up to 5 A at 250 VAC
  • 5-year limited warranty

Applications

  • Load Trending
  • Motor Control
  • Fan/Pump Status

Veris H932 Specifications

Sensor Power Induced from monitored conductor
Insulation Class 600 VAC RMS
Frequency Range 50/60 Hz
Temperature Range 5 to 140°F (-15 to 60°C)
Humidity Range 10 to 90% RH non-condensing
Accuracy ±2% FS from 10 to 100% (selected range)
Response Time 2 seconds
Terminal Block Wire Size 24 to 14 AWG (0.2 to 2.1 mm²)
Terminal Block Torque 3.5 to 4.4 in-lbs (0.4 to 0.5 N-m)
Warranty 5 years limited
Agency Approvals UL 508 open device listing, CAT III, Pollution Degree 2, basic insulation
Click here for complete specifications on the Veris H932

What's included with the Veris H932