1.800.561.8187

information@ITM.com

Customer Reviews

Dent PowerScout 24 Multi-Circuit Monitor

Dent PowerScout 24 Multi-Circuit Monitor-


Downloads: datasheet manual

Dent PowerScout 24 Multi-Circuit Monitor

Versatile multi-channel instrument featuring modular design that allows for monitoring multiple electrical circuits.

Versatile multi-channel instrument featuring modular design that allows for monitoring multiple electrical circuits.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Dent PS48HD-C-D-N PowerScout 48 HD Multi-Circuit Power Submeter with enclosure and display-

Dent PS48HD-C-D-N PowerScout 48 HD Multi-Circuit Power Submeter with enclosure and display

Model: PS48HD-C-D-N

Ideal for superior energy measurements, this versatile multi-circuit power submeter features 48 channels for monitoring voltage, current, power, energy, and many other electrical parameters on any combination of single and three-phase systems. In addition, this revenue-grade submeter comes with an enclosure and a display.


Recommended Accessories


Dent Instruments PowerScout PS24

Providing maximum flexibility for high-density monitoring. A versatile multi-channel instrument that allows for monitoring multiple electronic circuits or for current only monitoring of branch circuits.

The PowerScout PS24 can be supplied with virtually any combination of DENT's internally shunted split-core CTs. Allowing you to monitor any combination of up to 8 three-phase or 24 single-phase electrical devices.

Data updates every 1 second and accuracy that is better than 1%, mean the PS24 is well suited for data center monitoring, tenant sub-metering, and for accountability metering in commercial, retail, and industrial facilities.


Communications: Industry Standard Modbus or BACnet

Communications interface to the PowerScout 24 can be accomplished through standard serial RS-485 or USB, or optional Ethernet. The PowerScout can use either the BACnet IP or MS/TP protocol or Modbus TCP or RS-485 protocol for sending commands or retrieving data.


Fool-Proof Installation

The PowerScout series instruments are line powered and do not require external power. Its power supply can accommodate service voltages ranging from 80-600V (phase-to-phase). DENT's patented PhaseChek™ circuitry includes a 3 LED indicator display that confirms proper CT-to-phase installation.


Other Standard Features

Pulse Output
The PowerScout 24 features 8 digital outputs - one per meter element. Use these digital outputs to send kWh or other pulses to a pulse counting device, such as a datalogger.

Pulse Input
The PowerScout 24 has two digital input ports which are used to count, accumulate, and scale pulses received from non-DENT external pulse initiating meters such as gas, water, or other electrical meters.

Power Out
In addition, the PowerScout 24 has a 5VDC, 200mA power out to power other devices such as a radio or gateway device.

What's included with the Dent DENT-PS24

  • Dent PowerScout 24 Multi-Circuit Monitor

A Cost-Effective Solution for Electrical Load Profiling of Hospital Emergency Power Supply System Loads

ATS Multi-Circuit Metering Helps Effectively Manage Load Creep
Emergency Power Supply Systems (EPSS) are the critical infrastructure that supports a hospital system during power outages. Regulations place a lot of emphasis on testing and maintenance of the EPSS system; however, all the maintenance in the world will do no good if the EPSS becomes overloaded.

EPSS experience load creep like normal power systems. Additionally, they run the risk of reduced capacity due to the addition of non-essential loads plugged in to designated red receptacles during extended outages. These loads may consist of diagnostic equipment or in some cases “comfort equipment” such as microwaves, heaters or coffee pots. Education and training can help ensure only approved loads are plugged in to EPSS

You Can't Manage What You Don't Measure
The best way to manage your capacity is to submeter your loads. For some hospitals, this is easier said than done. While you may have submetering information at the generator switchgear or even downstream submetering at EPSS distribution switchgear, the ideal location to submeter for managing load creep is the load side of the automatic transfer switch (ATS).

Newer ATSs (installed within the last 10 years) either have digital controllers that incorporate submetering as an option, or engineers had the foresight to specify that OEMs install a separate third party submeter with the ATS. Unfortunately, older ATSs need to retrofit submeters to be able to measure the ATS load. This can be a costly proposition when considering hardware and installation costs. The combination of OSHA regulations, and the fact that the ATS is part of critical infrastructure, can make modifying equipment challenging.

A Cost-Effective Alternative to Conventional Circuit Monitoring
Within the last five years, a new type of electrical submeter has emerged and is an ideal solution for retrofitting ATSs with submetering capability. This meter type is referred to as the multi-circuit or multiple circuit meter. The concept is simple: Use one submeter CPU/circuit board to measure multiple loads.

A multi-circuit meter has only one set of inputs for a common voltage source, and multiple sets of current inputs for loads that share the common voltage source. Due to limitations on current transformer (CT: the instrument that provides current input to the meter) lead wire length, the multi-circuit meter is best suited for loads in which the CT installation locations for the loads are near one another (typically within 100 ft.).

Examples include: submetering all the circuits within a distribution panel, or all the distribution panels within an electric room, or feeder breakers on a unit substation. Since ATSs tend to be concentrated in electric rooms and typically share a common normal and emergency voltage source, they are great candidates for multi-circuit submeters.

What makes multi-circuit submetering so cost effective? The lower hardware and installation costs. Additionally, since there is only one CPU/circuit board, there is only one low-voltage communication connection.

Our general rule of thumb: whenever you have more than two loads to submeter that meet the criteria for multi-circuit metering, go with multi-circuit metering. Its costs will be lower when compared to individual meters.

Multi-Circuit Submeter Hardware
The DENT Instruments PowerScout 24 is a great example of an inexpensive yet accurate submeter that provides all the measurements necessary for monitoring ATS loads. DENT Instruments was one of the first companies to introduce the multi-circuit design.

The PowerScout 24 comes with its own enclosure, is powered via the voltage source and easily integrates to your SCADA or building automation system via Modbus or BACNet. It can measure up to 8 3-phase loads. List price for a PowerScout 24 with serial communication is $1,200. A DENT PowerScout 3037 (the single circuit meter version) is $400.

Taking in to account installation costs, it is easy to see how the multi-circuit meter is a cost-effective solution when you need to meter more than two loads that meet the multi-circuit criteria. The cost savings are even more substantial as the number of loads increases. A fully provisioned PowerScout 24 will have approximately 66% lower hardware costs when compared to individual meters. Taking in to account labor savings, the total costs savings can be as much as 80-90%.

Turn That Data Into Information
Submeters provide data. To make this data valuable, it needs to be turned into actionable information. To accomplish this, we recommend a few additional steps.

First, we recommend that submeter data be recorded. To be of benefit, the load profiles need to be analyzed over time using trending software within your SCADA or building automation system. If you don’t have an existing system, there are some very cost effective data logging devices that can store a large amount of interval data. This data can generally be exported and analyzed with a desktop application such as Microsoft Excel. We also recommend that the ATS switch position and generator run status also be recorded.

Using this information, it would be easy to analyze the data to check the load prior to the ATS switching to emergency, the load while on emergency, and the load after the ATS returns to the normal source. Using this analysis, it’s easy to identify loads added during a power outage and not removed when normal power is restored.

Another easy way to spot load creep is to trend year over year load growth. Using this analysis technique, load creep is easy to quantify.

Ultimately, multi-circuit submeters are an easily installed, inexpensive way for healthcare facility managers to conduct accurate load profiling and analysis.

Article by Affinity Energy

Accessories

Click on a category to view a selection of compatible accessories with the Dent PowerScout 24 Multi-Circuit Monitor.

Dent CT-HSC-020-U Mini Hinged Current Transformer, 20A CT-HSC-020-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 20A amp rating.
$45.36 CAD

was $48.00


Learn More

Dent CT-HSC-050-U Mini Hinged Current Transformer, 50A CT-HSC-050-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 50A amp rating.
$45.36 CAD

was $48.00


Learn More

Dent CT-HMC-0100-U Midi Hinged Current Transformer, 100A CT-HMC-0100-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 100A amp rating.
$109.62 CAD

was $116.00


Learn More

Dent CT-HMC-0200-U Midi Hinged Current Transformer, 200A CT-HMC-0200-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 200A amp rating.
$109.62 CAD

was $116.00


Learn More

Dent CT-SCM-0600-U Medium Split Core Current Transformer, 600A CT-SCM-0600-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 600A amp rating.
$118.13 CAD

was $125.00


Learn More

Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A CT-SCL-1000-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.
$142.70 CAD

was $151.00


Learn More

Ask a question about Dent PowerScout 24 Multi-Circuit Monitor

Customer Reviews for the Dent DENT-PS24

Dent Instruments PowerScout PS24

Providing maximum flexibility for high-density monitoring. A versatile multi-channel instrument that allows for monitoring multiple electronic circuits or for current only monitoring of branch circuits.

The PowerScout PS24 can be supplied with virtually any combination of DENT's internally shunted split-core CTs. Allowing you to monitor any combination of up to 8 three-phase or 24 single-phase electrical devices.

Data updates every 1 second and accuracy that is better than 1%, mean the PS24 is well suited for data center monitoring, tenant sub-metering, and for accountability metering in commercial, retail, and industrial facilities.


Communications: Industry Standard Modbus or BACnet

Communications interface to the PowerScout 24 can be accomplished through standard serial RS-485 or USB, or optional Ethernet. The PowerScout can use either the BACnet IP or MS/TP protocol or Modbus TCP or RS-485 protocol for sending commands or retrieving data.


Fool-Proof Installation

The PowerScout series instruments are line powered and do not require external power. Its power supply can accommodate service voltages ranging from 80-600V (phase-to-phase). DENT's patented PhaseChek™ circuitry includes a 3 LED indicator display that confirms proper CT-to-phase installation.


Other Standard Features

Pulse Output
The PowerScout 24 features 8 digital outputs - one per meter element. Use these digital outputs to send kWh or other pulses to a pulse counting device, such as a datalogger.

Pulse Input
The PowerScout 24 has two digital input ports which are used to count, accumulate, and scale pulses received from non-DENT external pulse initiating meters such as gas, water, or other electrical meters.

Power Out
In addition, the PowerScout 24 has a 5VDC, 200mA power out to power other devices such as a radio or gateway device.

What's included with the Dent DENT-PS24

  • Dent PowerScout 24 Multi-Circuit Monitor

A Cost-Effective Solution for Electrical Load Profiling of Hospital Emergency Power Supply System Loads

ATS Multi-Circuit Metering Helps Effectively Manage Load Creep
Emergency Power Supply Systems (EPSS) are the critical infrastructure that supports a hospital system during power outages. Regulations place a lot of emphasis on testing and maintenance of the EPSS system; however, all the maintenance in the world will do no good if the EPSS becomes overloaded.

EPSS experience load creep like normal power systems. Additionally, they run the risk of reduced capacity due to the addition of non-essential loads plugged in to designated red receptacles during extended outages. These loads may consist of diagnostic equipment or in some cases “comfort equipment” such as microwaves, heaters or coffee pots. Education and training can help ensure only approved loads are plugged in to EPSS

You Can't Manage What You Don't Measure
The best way to manage your capacity is to submeter your loads. For some hospitals, this is easier said than done. While you may have submetering information at the generator switchgear or even downstream submetering at EPSS distribution switchgear, the ideal location to submeter for managing load creep is the load side of the automatic transfer switch (ATS).

Newer ATSs (installed within the last 10 years) either have digital controllers that incorporate submetering as an option, or engineers had the foresight to specify that OEMs install a separate third party submeter with the ATS. Unfortunately, older ATSs need to retrofit submeters to be able to measure the ATS load. This can be a costly proposition when considering hardware and installation costs. The combination of OSHA regulations, and the fact that the ATS is part of critical infrastructure, can make modifying equipment challenging.

A Cost-Effective Alternative to Conventional Circuit Monitoring
Within the last five years, a new type of electrical submeter has emerged and is an ideal solution for retrofitting ATSs with submetering capability. This meter type is referred to as the multi-circuit or multiple circuit meter. The concept is simple: Use one submeter CPU/circuit board to measure multiple loads.

A multi-circuit meter has only one set of inputs for a common voltage source, and multiple sets of current inputs for loads that share the common voltage source. Due to limitations on current transformer (CT: the instrument that provides current input to the meter) lead wire length, the multi-circuit meter is best suited for loads in which the CT installation locations for the loads are near one another (typically within 100 ft.).

Examples include: submetering all the circuits within a distribution panel, or all the distribution panels within an electric room, or feeder breakers on a unit substation. Since ATSs tend to be concentrated in electric rooms and typically share a common normal and emergency voltage source, they are great candidates for multi-circuit submeters.

What makes multi-circuit submetering so cost effective? The lower hardware and installation costs. Additionally, since there is only one CPU/circuit board, there is only one low-voltage communication connection.

Our general rule of thumb: whenever you have more than two loads to submeter that meet the criteria for multi-circuit metering, go with multi-circuit metering. Its costs will be lower when compared to individual meters.

Multi-Circuit Submeter Hardware
The DENT Instruments PowerScout 24 is a great example of an inexpensive yet accurate submeter that provides all the measurements necessary for monitoring ATS loads. DENT Instruments was one of the first companies to introduce the multi-circuit design.

The PowerScout 24 comes with its own enclosure, is powered via the voltage source and easily integrates to your SCADA or building automation system via Modbus or BACNet. It can measure up to 8 3-phase loads. List price for a PowerScout 24 with serial communication is $1,200. A DENT PowerScout 3037 (the single circuit meter version) is $400.

Taking in to account installation costs, it is easy to see how the multi-circuit meter is a cost-effective solution when you need to meter more than two loads that meet the multi-circuit criteria. The cost savings are even more substantial as the number of loads increases. A fully provisioned PowerScout 24 will have approximately 66% lower hardware costs when compared to individual meters. Taking in to account labor savings, the total costs savings can be as much as 80-90%.

Turn That Data Into Information
Submeters provide data. To make this data valuable, it needs to be turned into actionable information. To accomplish this, we recommend a few additional steps.

First, we recommend that submeter data be recorded. To be of benefit, the load profiles need to be analyzed over time using trending software within your SCADA or building automation system. If you don’t have an existing system, there are some very cost effective data logging devices that can store a large amount of interval data. This data can generally be exported and analyzed with a desktop application such as Microsoft Excel. We also recommend that the ATS switch position and generator run status also be recorded.

Using this information, it would be easy to analyze the data to check the load prior to the ATS switching to emergency, the load while on emergency, and the load after the ATS returns to the normal source. Using this analysis, it’s easy to identify loads added during a power outage and not removed when normal power is restored.

Another easy way to spot load creep is to trend year over year load growth. Using this analysis technique, load creep is easy to quantify.

Ultimately, multi-circuit submeters are an easily installed, inexpensive way for healthcare facility managers to conduct accurate load profiling and analysis.

Article by Affinity Energy

Accessories

Click on a category to view a selection of compatible accessories with the Dent PowerScout 24 Multi-Circuit Monitor.

Dent CT-HSC-020-U Mini Hinged Current Transformer, 20A CT-HSC-020-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 20A amp rating.
$45.36 CAD

was $48.00


Learn More

Dent CT-HSC-050-U Mini Hinged Current Transformer, 50A CT-HSC-050-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 50A amp rating.
$45.36 CAD

was $48.00


Learn More

Dent CT-HMC-0100-U Midi Hinged Current Transformer, 100A CT-HMC-0100-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 100A amp rating.
$109.62 CAD

was $116.00


Learn More

Dent CT-HMC-0200-U Midi Hinged Current Transformer, 200A CT-HMC-0200-U
Features a high accuracy over a wide range with a superior phase shift that is ideal for areas where space is limited such as when metering multiples loads within an electrical panel. Offers a 200A amp rating.
$109.62 CAD

was $116.00


Learn More

Dent CT-SCM-0600-U Medium Split Core Current Transformer, 600A CT-SCM-0600-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 1.25" and offers a 600A amp rating.
$118.13 CAD

was $125.00


Learn More

Dent CT-SCL-1000-U Large Split Core Current Transformer, 1000A CT-SCL-1000-U
Provides a linear output voltage that is proportional to the input current that is safe and easy to install over existing electrical power lines without disconnection or interruption. Features a window size of 2.0" and offers a 1000A amp rating.
$142.70 CAD

was $151.00


Learn More

Ask a question about Dent PowerScout 24 Multi-Circuit Monitor

Customer Reviews for the Dent DENT-PS24

More Dent Products