1.800.561.8187

information@ITM.com

Customer Reviews

Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver

Model: R9120-5T | UPC: 07847757339

Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver-


Downloads: datasheet manual

Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver

Model: R9120-5T

The transceiver doubles the range of the R9120-3 with options for secure, encrypted wireless communications. It features a mesh technology design that makes connecting Modbus and pulse devices simple, as well as collect meter points in existing buildings with minimum downtime or disruption of day-to-day operations.

The transceiver doubles the range of the R9120-3 with options for secure, encrypted wireless communications. It features a mesh technology design that makes connecting Modbus and pulse devices simple, as well as collect meter points in existing buildings with minimum downtime or disruption of day-to-day operations.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Power Metering Accessories category for similar products.

Or let's do a search and help you find what you need:


Obvius R9120-5T Offers

The "smart" transceiver eliminates the need for costly wiring runs allowing users to capture meter data in the most challenging retrofit environments.

Features

  • Designed specifically for wireless metering
  • 256Bit AES, FIPS-197 certified, J/F-12 8306
  • No software or programming required
  • Devices automatically configure when powered
  • Wireless "mesh" network self-healing, self-optimizing
  • Frequency hopping, spread spectrum (FHSS)
  • Connect up to 32 Modbus and 2 pulse devices (expandable)
  • Visual display of signal strength (LEDs)
  • Multiple independent network capability
  • Reliable, constant two-way communication and packet verification
  • Point to multi-point communication
  • Field upgradable firmware

Wireless communication

Captures remote meter points that allow you to easily collect meter data from multiple buildings over long distances. The unique "mesh" technology provides optimized routing of communications with no pc or software configuration, meaning it works immediately "out of the box." This self-managed mesh network means that the system will function with high reliability where other wireless systems fail due to short- or long-term interference, and it can be used with any Modbus Master or gateway, making them an ideal solution for any project.

Compatibility

The ModHopper is compatible with virtually any PLC or Modbus RTU device, allowing the flexibility to use it in existing Modbus applications. The ModHopper is a "smart" device, which requires no programming. If used with the Obvius AcquiSuite, users can take advantage of numerous diagnostic tools, including a graphical display of the wireless mesh network.

Applications

  • Utility submetering (electric, gas, water, etc.)
  • Metering in existing buildings (retrofit)
  • Metering on campus environments
  • Government advanced metering projects (256Bit AES, FIPS-197 certified, J/F-12 8306)
  • Multi-tenant submetering projects
  • Industrial/manufacturing facilities
  • Demand response
  • Renewable energy – PV projects (inverters, string monitoring)

Obvius R9120-5T Specifications

Inputs
I/O 2x Pulse, dry contact, standard or KYZ, closure threshold 100 to 2.5 Ω user selectable
Pulse Rate User selectable to 10, 50, 100, 250 Hz
10 Hz: minimum pulse width 50 ms
50 Hz: minimum pulse width 10 ms
100 Hz: minimum pulse width 5 ms
250 Hz: minimum pulse width 2 ms
Storage Pulse counts stored in non-volatile memory
Modbus Modbus RTU, 2-wire, hard-wire connect up to 32 devices (expandable)
Communication
Protocols Modbus RTU, 2-wire
Addressing Modbus address may be set from 1 to 247 via dipswitch
Baud Rate 9600/19200 baud, N, 8, 1
RF 902 to 928 MHz ISM band, 1 W, frequency hopping spread spectrum (FHSS)
General Specifications
Processor 60 MHz ARM7 embedded CPU
LEDs 3 x RF, 2 x RS-485, 2 x Pulse, Alive, Alarm
Power Supply 9 to 30 VDC, 900 mA required
Operating Temperature -22 to 158°F (-30 to 70°C), 0 to 95% RH, non-condensing
CE 41 to 104°F (5 to 40°C), 0 to 90%, non-condensing
Altitude 6561.58' (2000 m) maximum
Pollution Degree 2
Dimensions 6.5 x 4.5 x 2" (260 x 64 x 45 mm)
Weight 1.25 lbs (0.67 kg)
FCC ID OUR-9XTEND or MCQ-XBPSX; FCC Part 15.247, Class A
IC (Industry Canada) 4214A-9XTEND or 1846A-XBPSX; IC: RSS-210
Encryption 256Bit AES
Click here for complete specifications on the Obvius R9120-5T

What's included with the Obvius R9120-5T

  • Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver

Ask a question about Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver

Customer Reviews for the Obvius R9120-5T

Obvius R9120-5T Offers

The "smart" transceiver eliminates the need for costly wiring runs allowing users to capture meter data in the most challenging retrofit environments.

Features

  • Designed specifically for wireless metering
  • 256Bit AES, FIPS-197 certified, J/F-12 8306
  • No software or programming required
  • Devices automatically configure when powered
  • Wireless "mesh" network self-healing, self-optimizing
  • Frequency hopping, spread spectrum (FHSS)
  • Connect up to 32 Modbus and 2 pulse devices (expandable)
  • Visual display of signal strength (LEDs)
  • Multiple independent network capability
  • Reliable, constant two-way communication and packet verification
  • Point to multi-point communication
  • Field upgradable firmware

Wireless communication

Captures remote meter points that allow you to easily collect meter data from multiple buildings over long distances. The unique "mesh" technology provides optimized routing of communications with no pc or software configuration, meaning it works immediately "out of the box." This self-managed mesh network means that the system will function with high reliability where other wireless systems fail due to short- or long-term interference, and it can be used with any Modbus Master or gateway, making them an ideal solution for any project.

Compatibility

The ModHopper is compatible with virtually any PLC or Modbus RTU device, allowing the flexibility to use it in existing Modbus applications. The ModHopper is a "smart" device, which requires no programming. If used with the Obvius AcquiSuite, users can take advantage of numerous diagnostic tools, including a graphical display of the wireless mesh network.

Applications

  • Utility submetering (electric, gas, water, etc.)
  • Metering in existing buildings (retrofit)
  • Metering on campus environments
  • Government advanced metering projects (256Bit AES, FIPS-197 certified, J/F-12 8306)
  • Multi-tenant submetering projects
  • Industrial/manufacturing facilities
  • Demand response
  • Renewable energy – PV projects (inverters, string monitoring)

Obvius R9120-5T Specifications

Inputs
I/O 2x Pulse, dry contact, standard or KYZ, closure threshold 100 to 2.5 Ω user selectable
Pulse Rate User selectable to 10, 50, 100, 250 Hz
10 Hz: minimum pulse width 50 ms
50 Hz: minimum pulse width 10 ms
100 Hz: minimum pulse width 5 ms
250 Hz: minimum pulse width 2 ms
Storage Pulse counts stored in non-volatile memory
Modbus Modbus RTU, 2-wire, hard-wire connect up to 32 devices (expandable)
Communication
Protocols Modbus RTU, 2-wire
Addressing Modbus address may be set from 1 to 247 via dipswitch
Baud Rate 9600/19200 baud, N, 8, 1
RF 902 to 928 MHz ISM band, 1 W, frequency hopping spread spectrum (FHSS)
General Specifications
Processor 60 MHz ARM7 embedded CPU
LEDs 3 x RF, 2 x RS-485, 2 x Pulse, Alive, Alarm
Power Supply 9 to 30 VDC, 900 mA required
Operating Temperature -22 to 158°F (-30 to 70°C), 0 to 95% RH, non-condensing
CE 41 to 104°F (5 to 40°C), 0 to 90%, non-condensing
Altitude 6561.58' (2000 m) maximum
Pollution Degree 2
Dimensions 6.5 x 4.5 x 2" (260 x 64 x 45 mm)
Weight 1.25 lbs (0.67 kg)
FCC ID OUR-9XTEND or MCQ-XBPSX; FCC Part 15.247, Class A
IC (Industry Canada) 4214A-9XTEND or 1846A-XBPSX; IC: RSS-210
Encryption 256Bit AES
Click here for complete specifications on the Obvius R9120-5T

What's included with the Obvius R9120-5T

  • Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver

Ask a question about Obvius R9120-5T ModHopper Wireless Modbus/Pulse Transceiver

Customer Reviews for the Obvius R9120-5T

More Obvius Products